Reference Guide
4-79
System Configuration and Operation Using the Broadcast Option
4.21.3 Test Access Digroups (TADS)
The Test Access Digroups (TADS) is a remote test access for data cross connects that pass
through the system according to publication TR-TSY-00033, Issue #1, June 1986.
A test center can access the system and assign split intrusive or non-intrusive monitor testing
circuits between the unit and the test center via another WAN link. For the purpose of this
discussion on Test Access Digroups, the figures show a 64kbps data circuit between Fremont,
CA. and Jacksonville, FL. Figure 4-52 shows the cross-connect screen with the data circuits
connected.
Figure 4-52. The TADS screen
In Figure 4-52, the data circuit called “Jacksonville” is connected on a single time slot between
WAN1-1 and WAN1-2.
Node_1 | C1 10161 CPU XCON COM 407535038 Ser 00101 | 12-31-99 14:33
page: 1 of 1
CIRCUIT ID FACILITY TEST EQUIPMENT TEST TYPE TC CNV
Jacksonville w1-1 01*64 off w1-2 01*64 off d moos n/a
moNitor | spLit | Release | Tla | pgUp | pgDn | Main