ADC Kentrox ISDN NT1 1010 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Sítě ADC Kentrox ISDN NT1 1010. ADC Kentrox ISDN NT1 1010 Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 552
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Integrated Access System
System Reference Guide
Publication 999-001989
Revision A0
Release 5.2
June 1999
Zobrazit stránku 0
1 2 3 4 5 6 ... 551 552

Shrnutí obsahu

Strany 1 - Publication 999-001989

Integrated Access SystemSystem Reference GuidePublication 999-001989Revision A0Release 5.2June 1999

Strany 2

Model No.Running Head5. See the UL Statement for Voice Cards.6. Never attempt to remove the power panel without first disconnecting input power cables

Strany 3 - Features in this Release

2-46 Reference GuideModel No.Running HeadRouting Server Applications2.10.1 Bundled Service DeploymentThe IP Routing Server is targeted at performing b

Strany 4 - System Cards

Reference Guide2-47Applications Routing Server2.10.2 Private Intranet DeploymentA secondary market for the IP Routing Server is private Intranet acces

Strany 5 - Voice Cards

2-48 Reference GuideModel No.Running HeadLow-Bit Rate Voice Server Applications2.10.3 IP Routing Server SpecificationsUp to three IP Routing server ca

Strany 6 - Data Cards

Reference Guide2-49Applications Low-Bit Rate Voice ServerHigh reliability in mission-critical installationsLBRV is suited to carrier networks and serv

Strany 7 - Optional Features

2-50 Reference GuideModel No.Running HeadLow-Bit Rate Voice Server Applications2.11.1 Call Center ApplicationIn the application shown in Figure 2-31,

Strany 8

Reference Guide2-51Applications Low-Bit Rate Voice Server2.11.2 Backhauling Voice ApplicationThe integrated access system equipped with a LBRV server

Strany 9 - User Card Reference Guides

2-52 Reference GuideModel No.Running HeadLow-Bit Rate Voice Server Applications2.11.3 Extending Voice Access ApplicationThe application shown in Figur

Strany 10 - Running Head

Reference Guide3-1System Installation IntroductionChapter 3System Installation3.1 IntroductionThis chapter provides instructions for unpacking and ins

Strany 11 - WARNING!

3-2 Reference GuideModel No.Running HeadChassis Installation System Installation3.3.2 Pre-Installation Tips3.3.2.1 Installation ChecklistInstall your

Strany 12 - Grounding

Reference Guide3-3System Installation Chassis Installation3.3.3 Choosing a Location for Your SystemThe integrated access system requires a reasonably

Strany 13

WARNING!This equipment has been tested and found to comply with the limits for a Class"A" Digital Device, pursuant to Part 15 of the FCC Rul

Strany 14

3-4 Reference GuideModel No.Running HeadChassis Installation System Installation3.3.3.2 Wall-Mount Installation TipsTo mount the chassis on a wall, fi

Strany 15 - FCC Part 68 Information

Reference Guide3-5System Installation Chassis InstallationThe brackets are also reversible for mounting in 19-inch or 23-inch racks (48.2 or 58.4 cm).

Strany 16 - Declaration of Conformity

3-6 Reference GuideModel No.Running HeadChassis Installation System InstallationFigure 3-3. Mounting Holes for Front-Loading Chassis with Power Suppli

Strany 17

Reference Guide3-7System Installation Power Supplies and Ringing GeneratorsBe sure both the front and rear of the chassis are accessible for inserting

Strany 18 - UK Compliance Statements

3-8 Reference GuideModel No.Running HeadPower Supplies and Ringing Generators System Installation3.4.3 Setting the U.S./European Configuration JumperB

Strany 19

Reference Guide3-9System Installation Power Supplies and Ringing Generators3.4.6 AC Power Supply and DC Supply FusesThe AC power supply and DC Power S

Strany 20

3-10 Reference GuideModel No.Running HeadRinging Generators System InstallationNote:There are two different types of 100W -48V Converters; one with fu

Strany 21 - Contents

Reference Guide3-11System Installation Ringing Generators3.5.1 Ringing Generators (8906/890620)Ringing generators are needed if the system has FXS or

Strany 22

3-12 Reference GuideModel No.Running HeadRinging Generators System Installation11. Hold the unit by its metal handle and align the PCB edges with the

Strany 23

Reference Guide3-13System Installation System Power and Ground Connections3.6 System Power and Ground ConnectionsAfter installing the system power car

Strany 24

Model No.Running HeadFusingTo avoid a fire hazard, use only fuses with the specified type and rating.Power Supply Safety InformationThe following info

Strany 25

3-14 Reference GuideModel No.Running HeadSystem Power and Ground Connections System InstallationFigure 3-8. D/C Terminal Block on Front-Loading Chassi

Strany 26

Reference Guide3-15System Installation System Power and Ground ConnectionsFigure 3-9. A/C Power Connector on Front-Loading Chassis with Power Supplies

Strany 27

3-16 Reference GuideModel No.Running HeadSystem Power and Ground Connections System Installation3.6.2 Two-Sided Chassis (891830)Figure 3-10 shows the

Strany 28

Reference Guide3-17System Installation System Power and Ground Connections Figure 3-10. D/C Terminal Block on Two-Sided Chassiswith Power Supplies on

Strany 29

3-18 Reference GuideModel No.Running HeadSystem Power and Ground Connections System InstallationFigure 3-11. A/C Power Connector on Two-Sided Chassisw

Strany 30

Reference Guide3-19System Installation System Power and Ground Connections3.6.3 Power Enhanced Chassis with Power Supplies in Front (891930)Figure 3-1

Strany 31

3-20 Reference GuideModel No.Running HeadSystem Power and Ground Connections System InstallationFigure 3-12. D/C Terminal Block on Enhanced Chassiswit

Strany 32

Reference Guide3-21System Installation System Power and Ground ConnectionsFigure 3-13. Power Enhanced Chassis with Power Supplies on Top in an A/C Env

Strany 33

3-22 Reference GuideModel No.Running HeadPowering Up the System System Installation3.7 Powering Up the SystemAfter connecting the chassis to the exter

Strany 34

Reference Guide3-23System Installation Installing the Other Plug-In Cards3.8.2 CPU Card (8803)Install a CPU-5 XCON Card into slot C1 of the system cha

Strany 35

Electrostatic Discharge PreventionThe plug-in cards contain components that could be damaged by electrostatic discharge. When handling any cards, wear

Strany 36

3-24 Reference GuideModel No.Running HeadInstalling the Other Plug-In Cards System Installation3.8.5 User CardsThe system also has numerous user cards

Strany 37

Reference Guide4-1System Configuration and Operation Basic OperationsChapter 4System Configuration and Operation4.1 Basic OperationsThis chapter provi

Strany 38

4-2 Reference GuideModel No.Running HeadSystem Initialization System Configuration and Operation4.3.1 RegistrationTo register your system after starti

Strany 39

Reference Guide4-3System Configuration and Operation System Initialization6. Enter password as shown in Figure 4-2. Refer to Table 4-1 for default pas

Strany 40

4-4 Reference GuideModel No.Running HeadSystem Initialization System Configuration and Operation7. Enter your vendor code in the Vendor Code field. Se

Strany 41

Reference Guide4-5System Configuration and Operation System Initialization8. Select the type of chassis used (front-loading with power supplies on the

Strany 42

4-6 Reference GuideModel No.Running HeadSystem Initialization System Configuration and OperationFigure 4-5. Testing and Initialization ScreenThe syste

Strany 43 - System Overview

Reference Guide4-7System Configuration and Operation System Initialization4.3.2 Logging Into the SystemThe first step in starting an operator session

Strany 44 - Chassis Types System Overview

4-8 Reference GuideModel No.Running HeadSystem Initialization System Configuration and OperationFigure 4-6. Typical Login Screen3. Contact your system

Strany 45 - System Overview Chassis Types

Reference Guide4-9System Configuration and Operation System InitializationFigure 4-7. Typical System Main Screen(Two-Sided Chassis and Front-Loading C

Strany 46

Model No.Running Head

Strany 47

4-10 Reference GuideModel No.Running HeadSystem Initialization System Configuration and OperationFigure 4-8. Typical System Main Screen(Front-Loading

Strany 48

Reference Guide4-11System Configuration and Operation System Screens4.4 System ScreensThe system screen will display each card that is currently insta

Strany 49

4-12 Reference GuideModel No.Running HeadSystem Screens System Configuration and Operation4.4.2 Voice and Data Card StatusThe System Main Screen also

Strany 50

Reference Guide4-13System Configuration and Operation System Screens4.4.3 Server Card StatusPort status for the ADPCM and ISDN-PRI Server cards is det

Strany 51 - Ringer Supports

4-14 Reference GuideModel No.Running HeadSystem Screens System Configuration and OperationThe status for these ATM ports is represented by four charac

Strany 52

Reference Guide4-15System Configuration and Operation System ScreensFigure 4-10. Typical Card Main ScreenThe bottom line of each Card Main Screen list

Strany 53

4-16 Reference GuideModel No.Running HeadCard Configuration System Configuration and Operation4.4.5 Test and Debug ScreenYou can also go from the Syst

Strany 54

Reference Guide4-17System Configuration and Operation Card ConfigurationBe sure to configure each card according to your networking requirements. From

Strany 55 - Applications

4-18 Reference GuideModel No.Running HeadReinitializing the System System Configuration and Operation4.6 Reinitializing the SystemThe system stores in

Strany 56 - 2.2 Sample Applications

Reference Guide4-19System Configuration and Operation Reinitializing the SystemFigure 4-11. Cold-Start NVRAM Test Screen.WARNING!The "Z" com

Strany 57

Regulatory Compliance InformationFCC Part 68 InformationThis equipment complies with Part 68 of the FCC rules.The equipment has FCC Registration Numbe

Strany 58 - 2.3.3 E&M Card

4-20 Reference GuideModel No.Running HeadAlarms System Configuration and Operation4.7 AlarmsAlarms warn you of problems by reporting possible system h

Strany 59

Reference Guide4-21System Configuration and Operation AlarmsThe first character set (00023 in the above display) is the Alarm Sequence Number. This is

Strany 60 - 2.3.5 TR008 Application

4-22 Reference GuideModel No.Running HeadAlarms System Configuration and Operation4.7.2 Alarm Filter SettingsYou can set filters for each alarm so tha

Strany 61

Reference Guide4-23System Configuration and Operation AlarmsThe fourth column of the Alarm Filters Screen contains the filter modifiers info, minor, m

Strany 62 - 2.4.1 HSU Card

4-24 Reference GuideModel No.Running HeadAlarms System Configuration and OperationTable 4-3. Alarm FiltersFilter Alarm MeaningOOS Out of Service The c

Strany 63

Reference Guide4-25System Configuration and Operation Alarms4.7.3 Alarm ModifiersEach alarm may also be designated as I=info, m=minor, M=major or C=cr

Strany 64 - 2.4.3 SRU Card

4-26 Reference GuideModel No.Running HeadAlarms System Configuration and Operation4. In earlier software releases, if an operator erroneously attempte

Strany 65 - IAD w/ SRU

Reference Guide4-27System Configuration and Operation AlarmsFigure 4-14. Typical Alarm History ScreenNode_1 |

Strany 66 - 2.4.4 FRAD Card

4-28 Reference GuideModel No.Running HeadTime Slot Configuration Screen System Configuration and Operation4.8 Time Slot Configuration ScreenFrom the S

Strany 67 - 2.4.5 OCU-DP Card

Reference Guide4-29System Configuration and Operation System Level Maintenance4.12.1 Test, Debug, Backup & RestoreAdvanced configuration and diagn

Strany 68

Model No.Running HeadCE MarkingThe CE mark is affixed to those chassis that conform to the following Commission Directives:•89/336/EEC on the approxim

Strany 69 - 2.4.6 BRI Card

4-30 Reference GuideModel No.Running HeadSystem Level Maintenance System Configuration and Operation4.12.2 Zipping the SystemFigure 4-16 shows a typic

Strany 70 - 2.4.6.1 BRI Card Models

Reference Guide4-31System Configuration and Operation System Level Maintenance4.12.3 Debugging the SystemThe D (Debug) command is only available to fa

Strany 71 - 2.4.7 DSO-DP Card

4-32 Reference GuideModel No.Running HeadSystem Level Maintenance System Configuration and Operation4.12.5 Pre-TFTP Backup and Restore PreparationTo p

Strany 72

Reference Guide4-33System Configuration and Operation System Level Maintenance6. Press “G” for Go - an NV image overwrite command confirmation appears

Strany 73

4-34 Reference GuideModel No.Running HeadSystem Level Maintenance System Configuration and Operation10. Following completion of the restoration proces

Strany 74 - T1/E1 carrier

Reference Guide4-35System Configuration and Operation System Level Maintenance5. From the Terminal Emulation Screen Menu select Send Text File. The sy

Strany 75 - . . . . .

4-36 Reference GuideModel No.Running HeadTaking a Card Out of Service System Configuration and Operation11. From the terminal screen select “Receive F

Strany 76

Reference Guide4-37System Configuration and Operation CPU Switching4.14 CPU SwitchingThe 5.2 host release provides CPU redundancy switching by pressin

Strany 77

4-38 Reference GuideModel No.Running HeadAssigning Time Slots System Configuration and Operation4.15.1 Modes of OperationIn the 5.x system, the only m

Strany 78

Reference Guide4-39System Configuration and Operation Assigning Time SlotsFigure 4-17. Typical E&M Card Time Slot Assignments4.16.2 Assigning Mult

Strany 79 - Provider

Country-Specific Regulatory Compliance InformationCanadaCanadian DOC InformationNOTICE TO USERS OF THE CANADIAN TELEPHONE NETWORKThe Canadian Departme

Strany 80 - Backbone

4-40 Reference GuideModel No.Running HeadAssigning Time Slots System Configuration and Operation4. Place an “x” under each desired time slot, using th

Strany 81

Reference Guide4-41System Configuration and Operation Assigning Time SlotsFigure 4-19. Typical HSU Card Time Slot Assignments for E14.16.3 Cross-Conne

Strany 82

4-42 Reference GuideModel No.Running HeadAutomatic Time Slot Assignment System Configuration and Operation4.17 Automatic Time Slot AssignmentYou can a

Strany 83 - 2.6.7 Routing Capabilities

Reference Guide4-43System Configuration and Operation Automatic Time Slot Assignment5. Select the WAN port to which you want to assign the voice cards

Strany 84

4-44 Reference GuideModel No.Running HeadAutomatic Time Slot Assignment System Configuration and OperationFigure 4-22. Typical WAN Card SelectionNode_

Strany 85

Reference Guide4-45System Configuration and Operation Automatic Time Slot AssignmentFigure 4-23. Typical System Main Screen with AlarmsIn Figure 4-24,

Strany 86

4-46 Reference GuideModel No.Running HeadCross-Connecting WAN Time Slots System Configuration and OperationFigure 4-24. Typical WAN Time Slot Assignme

Strany 87

Reference Guide4-47System Configuration and Operation Cross-Connecting WAN Time SlotsFigure 4-25. Typical CPU Cross-Connect ScreenNode_1 | C1

Strany 88

4-48 Reference GuideModel No.Running HeadCross-Connecting WAN Time Slots System Configuration and OperationFigure 4-26. Add a Cross-Connect Circuit Sc

Strany 89

Reference Guide4-49System Configuration and Operation Cross-Connecting WAN Time SlotsTable 4-4. Time Slot Cross-Connection Option Settings and Default

Strany 90

Model No.Running HeadJapanClass A ITE NotificationEuropeEuropean Telecommunication ApprovalsUnder the Telecommunications Terminal Directive the follow

Strany 91

4-50 Reference GuideModel No.Running HeadCross-Connecting WAN Time Slots System Configuration and OperationWARNING!When cross-connecting multiple inde

Strany 92

Reference Guide4-51System Configuration and Operation Cross-Connecting WAN Time Slotsuses the same convention (w1-1, w1-2, etc.) seen earlier. If a WA

Strany 93 - 56/64Kbps

4-52 Reference GuideModel No.Running HeadCross-Connecting WAN Time Slots System Configuration and OperationFigure 4-29. Time Slot and Bandwidth Option

Strany 94

Reference Guide4-53System Configuration and Operation Cross-Connecting WAN Time SlotsFigure 4-30. Test OptionsW/UThe second WAN Unit column is the T1/

Strany 95 - 2.9 ATM Server Card

4-54 Reference GuideModel No.Running HeadCross-Connecting WAN Time Slots System Configuration and OperationMake your selection with the space bar and

Strany 96 - ATM Server Card Applications

Reference Guide4-55System Configuration and Operation Cross-Connecting WAN Time SlotsFigure 4-31. Cross-Connect Circuit Type SelectionTCYou can define

Strany 97 - ATM Edge Switch

4-56 Reference GuideModel No.Running HeadCross-Connecting WAN Time Slots System Configuration and OperationIf you choose user, also enter a two-digit

Strany 98

Reference Guide4-57System Configuration and Operation Cross-Connecting WAN Time SlotsFigure 4-33. Signaling Bit Pattern SelectionNode_1 | C1

Strany 99 - 2.10 Routing Server

4-58 Reference GuideModel No.Running HeadCross-Connecting WAN Time Slots System Configuration and OperationFigure 4-34. Voice Options ScreenCNVThe Con

Strany 100 - Routing Server Applications

Reference Guide4-59System Configuration and Operation Cross-Connecting WAN Time SlotsThe ANSI-CCITT setting will convert the incoming ANSI signaling t

Strany 101 - Reference Guide

The approved CEPT configuration options are shown below.The Interface Card is also listed in the approval documentation and provides a direct metallic

Strany 102

4-60 Reference GuideModel No.Running HeadCross-Connecting WAN Time Slots System Configuration and OperationFigure 4-36. Selecting Signaling Conversion

Strany 103

Reference Guide4-61System Configuration and Operation Cross-Connecting WAN Time SlotsFigure 4-37. Typical Completed CircuitsNode_1 | C1 CPU X

Strany 104 - Router Router

4-62 Reference GuideModel No.Running HeadCross-Connect Actions System Configuration and Operation4.19 Cross-Connect ActionsTable 4-5 summarizes the ac

Strany 105

Reference Guide4-63System Configuration and Operation Cross-Connect ActionsTo update a cross-connected circuit from the CPU Cross-Connect Screen, high

Strany 106

4-64 Reference GuideModel No.Running HeadCross-Connect Actions System Configuration and OperationTo delete a cross-connected circuit from the CPU Cros

Strany 107 - Chapter 3

Reference Guide4-65System Configuration and Operation Testing Voice Cross-Connects4.20 Testing Voice Cross-ConnectsVoice and data circuits differ in t

Strany 108 - 3.3.2 Pre-Installation Tips

4-66 Reference GuideModel No.Running HeadTesting Voice Cross-Connects System Configuration and OperationFigure 4-41. Highlighted Circuit on a WAN Cros

Strany 109

Reference Guide4-67System Configuration and Operation Testing Voice Cross-ConnectsTable 4-6. WAN Cross-Connect Test Screen Option Settings and Defaul

Strany 110 - 3.3.4 Installing the Chassis

4-68 Reference GuideModel No.Running HeadTesting Voice Cross-Connects System Configuration and OperationPATTERNThe Pattern parameter allows you to cho

Strany 111 - Holes for Tabletop Attachment

Reference Guide4-69System Configuration and Operation Using the Broadcast Option4.21 Using the Broadcast OptionOne of the special features of WAN time

Strany 112

Model No.Running HeadTrademarks:5ESS is a registered trademark of Lucent TechnologiesDMS-100 and DMS-200 are trademarks of Northern Telecom.Nortel is

Strany 113 - Centimeters 25 38 2 5

Model No.Running HeadGermanyGerman Approval NumberThe German approval number is A118 142F.Safety WarningSPEZIFISCHE SICHERHEITSMAßNAHMENDIE EINRICHTUN

Strany 114 - CAUTION!

4-70 Reference GuideModel No.Running HeadUsing the Broadcast Option System Configuration and OperationFigure 4-44. Typical Main Cross-Connect ScreenBr

Strany 115

Reference Guide4-71System Configuration and Operation Using the Broadcast OptionFigure 4-45. Typical All Circuits ScreenIn addition to the two WAN-to-

Strany 116 - 3.5 Ringing Generators

4-72 Reference GuideModel No.Running HeadUsing the Broadcast Option System Configuration and OperationFigure 4-46. Typical Add Broadcast ScreenIn this

Strany 117

Reference Guide4-73System Configuration and Operation Using the Broadcast OptionFigure 4-47. Typical "To" Destination SelectionNode_1

Strany 118

4-74 Reference GuideModel No.Running HeadUsing the Broadcast Option System Configuration and OperationFigure 4-48. Typical Time Slot SelectionNode_1

Strany 119

Reference Guide4-75System Configuration and Operation Using the Broadcast OptionFigure 4-49. Typical Complete Broadcast CircuitNode_1 | C1 CPU

Strany 120

4-76 Reference GuideModel No.Running HeadUsing the Broadcast Option System Configuration and OperationFigure 4-50. Three Broadcast CircuitsNode_1

Strany 121 - Side in a A/C Environment

Reference Guide4-77System Configuration and Operation Using the Broadcast OptionFigure 4-51. Typical Deleted Broadcast Circuit4.21.1 WAN Link to WAN L

Strany 122

4-78 Reference GuideModel No.Running HeadUsing the Broadcast Option System Configuration and Operation4.21.2 Broadcast Screen ActionsTable 4-7 lists t

Strany 123 - Model: IMACS/800

Reference Guide4-79System Configuration and Operation Using the Broadcast Option4.21.3 Test Access Digroups (TADS)The Test Access Digroups (TADS) is a

Strany 124

Reference GuideiContentsContentsChapter 1 System Overview1.1 Introduction ...

Strany 125

4-80 Reference GuideModel No.Running HeadUsing the Broadcast Option System Configuration and Operation4.21.4 Monitor CircuitWith the monitor circuit,

Strany 126

Reference Guide4-81System Configuration and Operation Using the Broadcast OptionFigure 4-54. Completed Monitor CircuitFigure 4-55 shows a diagram of h

Strany 127 - AC “third wire” Ground

4-82 Reference GuideModel No.Running HeadUsing the Broadcast Option System Configuration and OperationFigure 4-55. Monitor Circuit DiagramFremont DTEJ

Strany 128 - 3.7 Powering Up the System

Reference Guide4-83System Configuration and Operation Using the Broadcast Option4.21.5 Split CircuitPressing the “L” command from the Menu of Actions

Strany 129 - 3.8.4 Server Cards

4-84 Reference GuideModel No.Running HeadUsing the Broadcast Option System Configuration and OperationFigure 4-57. Split Circuit DiagramFremont DTEJac

Strany 130 - 3.8.5 User Cards

Reference Guide4-85System Configuration and Operation Using the Broadcast Option4.21.6 ReleasePressing the “R” (Release) command allows you to release

Strany 131 - Chapter 4

4-86 Reference GuideModel No.Running HeadUsing the Broadcast Option System Configuration and Operation4.21.7 Terminate and Leave AccessThe Terminate a

Strany 132 - 4.3.1 Registration

Reference Guide4-87System Configuration and Operation Using the Broadcast OptionTable 4-8. TLA Circuit State Screen Menu of ActionsAction FunctionmoN

Strany 133

4-88 Reference GuideModel No.Running HeadChecking the Time Slot Map System Configuration and Operation4.22 Checking the Time Slot MapOnce you select a

Strany 134

Reference Guide4-89System Configuration and Operation Checking the Time Slot MapFor E1 transmission (Figure 4-61), time slot 0 and 16 are not availabl

Strany 135

ii Reference GuideModel No.Running HeadContents2.6.7 Routing Capabilities ...

Strany 136

4-90 Reference GuideModel No.Running HeadRecording the Time Slot ConfigurationSystem Configuration and Operation4.23 Recording the Time Slot Configura

Strany 137 - 4.3.2 Logging Into the System

Reference Guide4-91System Configuration and OperationRecording the Time Slot ConfigurationTable 4-10. Time Slot Recording Form for E1 OperationWAN Po

Strany 138

4-92 Reference GuideModel No.Running HeadRedundant Operations System Configuration and Operation4.24 Redundant OperationsThis section describes the re

Strany 139

Reference Guide4-93System Configuration and Operation CPU Card RedundancyFigure 4-62. Typical Redundant-Power Supply System Main Screen4.26 CPU Card R

Strany 140

4-94 Reference GuideModel No.Running HeadCPU Card Redundancy System Configuration and OperationFigure 4-63. Manually Switching to a Redundant CPUAt th

Strany 141 - 4.4 System Screens

Reference Guide4-95System Configuration and Operation WAN Card RedundancyFigure 4-64. Typical System with CPU Switchover Completed4.27 WAN Card Redund

Strany 142

4-96 Reference GuideModel No.Running HeadWAN Card Redundancy System Configuration and OperationDuring a WAN redundancy switch, voice and data traffic

Strany 143 - 4.4.3 Server Card Status

Reference Guide4-97System Configuration and Operation WAN Card RedundancyFigure 4-65. Typical Cross-Connect System with WAN Card RedundancyFigure 4-66

Strany 144 - 4.4.4 Card Main Screens

4-98 Reference GuideModel No.Running HeadWAN Card Redundancy System Configuration and OperationFigure 4-66. Switching to a Redundant Cross-Connect WAN

Strany 145

Reference Guide4-99System Configuration and Operation ADPCM Card RedundancyFigure 4-67. Typical Cross-Connect WAN Card Redundancy Switch in Progress4.

Strany 146 - 4.5 Card Configuration

Reference GuideiiiContents3.4.4 Installing the System Power Cards...3-83.4.5 Talk Battery Su

Strany 147

4-100 Reference GuideModel No.Running HeadADPCM Card Redundancy System Configuration and OperationFigure 4-68. Typical System with Redundant ADPCM Car

Strany 148 - 4.6 Reinitializing the System

Reference Guide4-101System Configuration and Operation ADPCM Card RedundancyTo choose a redundant ADPCM card for the system, proceed as follows:1. Go

Strany 149

4-102 Reference GuideModel No.Running HeadADPCM Card Redundancy System Configuration and Operation

Strany 150 - 4.7 Alarms

Reference Guide5-1CPU Card IntroductionChapter 5CPU Card5.1 IntroductionThe CPU is the “brain” of the Integrated Access System and performs most of th

Strany 151

5-2 Reference GuideModel No.Running HeadCPU Card Descriptions CPU Card5.2.1.1 Card Jumper/Switch SettingsThe CPU XCON Card has US/Euro jumpers on its

Strany 152 - 4.7.2 Alarm Filter Settings

Reference Guide5-3CPU Card CPU Card User Screens and Settings5.3 CPU Card User Screens and SettingsThe CPU card has several user interface screens for

Strany 153

5-4 Reference GuideModel No.Running HeadCPU Card User Screens and Settings CPU CardThe bottom highlighted line of the above screen shows a series of a

Strany 154

Reference Guide5-5CPU Card CPU Card User Screens and SettingsMANAGER, OPERATOR, AND VIEWER The other three passwords are, "Manager," "O

Strany 155 - 4.7.4 Alarm Cutoff (ACO)

5-6 Reference GuideModel No.Running HeadCPU Card User Screens and Settings CPU CardALRM SEQThe Alarm Sequence setting establishes how the sequence num

Strany 156 - 4.7.6 Alarm Handling

Reference Guide5-7CPU Card CPU Card User Screens and SettingsFigure 5-3. Typical CPU Print Alarm ScreenTable 5-2 lists the operations that can be perf

Strany 157

iv Reference GuideModel No.Running HeadContents4.7.5 Backplane Out of Service (BP_OOS)... 4-254.7.6

Strany 158 - 4.12 System Level Maintenance

5-8 Reference GuideModel No.Running HeadCPU Card User Screens and Settings CPU CardTable 5-3. Print Alarm Screen Option Settings and DefaultsNotes:1.

Strany 159

Reference Guide5-9CPU Card CPU Card User Screens and SettingsPRT PHONE#The Print Phone Number field shows the number the modem dials to report alarms

Strany 160 - 4.12.2 Zipping the System

5-10 Reference GuideModel No.Running HeadTCP/IP Network Management CPU CardWhen the specified interval cycle for major or minor alarms is reached, the

Strany 161 - 4.12.4 Registering the System

Reference Guide5-11CPU Card TCP/IP Network Management(Facility Data Link) of an ESF-framed T1 link, the SA4 on an E1 link, a B7R formatted DS0 on a T1

Strany 162 - 4.12.6 TFTP Backup for 5.x.x

5-12 Reference GuideModel No.Running HeadTCP/IP Network Management CPU CardFigure 5-6 shows the TCP/IP Screen. To access this screen, press “I” (tcp/I

Strany 163 - 4.12.7 TFTP Restore for 5.x.x

Reference Guide5-13CPU Card TCP/IP Network ManagementTable 5-5. TCP/IP Screen Option Settings and DefaultsHOST IP STATEThis parameter determines wheth

Strany 164 - 4.12.8 ASCII Backup Procedure

5-14 Reference GuideModel No.Running HeadTCP/IP Network Management CPU CardHOST NETMASKThe Host Netmask is used to indicate how much of the IP address

Strany 165

Reference Guide5-15CPU Card TCP/IP Network ManagementFigure 5-7. CPU Default IP Port Selection ScreenDEFAULT IP SLOTThe Default IP Slot options are de

Strany 166

5-16 Reference GuideModel No.Running HeadTCP/IP Network Management CPU CardDEFAULT IP UNITThe Default IP Unit (Figure 5-8) options are determined by t

Strany 167 - 4.15 Time Slot Assignment

Reference Guide5-17CPU Card TCP/IP Network ManagementRPT1 COMMUN STRThe RPT1 Community String holds the community string for the first NMS host runnin

Strany 168 - 4.16 Assigning Time Slots

Reference GuidevContentsChapter 5 CPU Card5.1 Introduction ...

Strany 169

5-18 Reference GuideModel No.Running HeadTCP/IP Network Management CPU Card5.4.1 Network Statistics ScreensThe Network Statistics Screens provide main

Strany 170

Reference Guide5-19CPU Card TCP/IP Network ManagementTable 5-6. Network Statistics Screen Actions5.4.1.1 SLIP ParametersThe Serial Line Interface Pro

Strany 171 - 4.16.3 Cross-Connect Model

5-20 Reference GuideModel No.Running HeadTCP/IP Network Management CPU CardBuffer OverflowThe Buffer Overflow field shows the occurrences of buffer ov

Strany 172

Reference Guide5-21CPU Card TCP/IP Network ManagementFrames TransmittedThe Frames Transmitted field shows the number of frames sent from the local sys

Strany 173

5-22 Reference GuideModel No.Running HeadTCP/IP Network Management CPU CardDatagrams ReceivedThe Datagrams Received field shows the number of IP datag

Strany 174

Reference Guide5-23CPU Card TCP/IP Network Management5.4.1.4 ICMP ParametersThe ICMP parameters also appear in the second Network Statistics Screen (F

Strany 175

5-24 Reference GuideModel No.Running HeadTCP/IP Network Management CPU CardFigure 5-11. Typical Network Statistics Screen, Page 3Packets ReceivedThe P

Strany 176

Reference Guide5-25CPU Card TCP/IP Network ManagementPackets Discarded - WindowThe Packets Discarded - Window field shows the number of TCP packets th

Strany 177

5-26 Reference GuideModel No.Running HeadTCP/IP Network Management CPU CardRTT IncreasedThe RTT Increased field shows the number of times the retransm

Strany 178

Reference Guide5-27CPU Card TCP/IP Network Management5.4.1.6 UDP ParametersThe UDP parameters appear in the fourth Network Statistics Screen (Figure 5

Strany 179 - CIRCUIT ID

vi Reference GuideModel No.Running HeadContents6.2.1.3 External Sync Panel...

Strany 180

5-28 Reference GuideModel No.Running HeadTCP/IP Network Management CPU Card5.4.1.7 TELNET ParametersThe TELNET parameters also appear in the fourth Ne

Strany 181 - Figure 4-28. WAN Unit Options

Reference Guide5-29CPU Card TCP/IP Network ManagementSessions ClosedThe Sessions Closed field shows the total number of sessions that were closed by t

Strany 182

5-30 Reference GuideModel No.Running HeadIP Packet Routing CPU Card5.5 IP Packet RoutingThe integrated access system supports multipoint routing of In

Strany 183 - Figure 4-30. Test Options

Reference Guide5-31CPU Card IP Packet RoutingFigure 5-13. Example Routing DiagramIn Figure 5-13, 24 system units transmit alarm information to an IP r

Strany 184

5-32 Reference GuideModel No.Running HeadIP Packet Routing CPU CardFigure 5-14. Typical IP Routing ScreenTable 5-7. Routing Screen ActionsAction Funct

Strany 185

Reference Guide5-33CPU Card IP Packet RoutingTable 5-8. IP Routing Screen Option Settings and DefaultsIP NETThe IP Net field shows the IP address of a

Strany 186

5-34 Reference GuideModel No.Running HeadIP Packet Routing CPU CardDelete a RouteIn the Routing Screen, scroll to the route to be deleted. With the ro

Strany 187

Reference Guide5-35CPU Card IP Packet RoutingFigure 5-15. Routing Address Entry Screen Node_1 | C1 CPU XCON Rev XA-0 Ser 00009 | 1

Strany 188

5-36 Reference GuideModel No.Running HeadIP Packet Routing CPU CardFigure 5-16. Slot/Unit Options ScreenTable 5-9. Slot/Unit Option Settings and Defa

Strany 189

Reference Guide5-37CPU Card IP Packet RoutingFigure 5-17. IP Static Routing Information Screen Node_1 | C1 CPU XCON Rev XA-0 Ser 00009

Strany 190

Reference GuideviiContents7.3.1.1 DSX/CEPT Module Jumper Settings...7-57.3.1.2 DSX/CEPT Module Insta

Strany 191

5-38 Reference GuideModel No.Running HeadIP Packet Routing CPU Card5.5.1 nX64 ScreenThe Enhanced NMS Connectivity screen (Figure 5-18) provides a solu

Strany 192 - 4.19 Cross-Connect Actions

Reference Guide5-39CPU Card IP Packet RoutingThe four available channels may be configured at nx64 kpbs, using plain HDLC for communication with other

Strany 193

5-40 Reference GuideModel No.Running HeadIP Packet Routing CPU CardFORMATThe format indicates which format is selected for the given nX64 communicatio

Strany 194

Reference Guide5-41CPU Card IP Packet Routing5.5.2 Network Statistics ScreenFigure 5-19 shows the Netstat screen for the network statistics at the int

Strany 195

5-42 Reference GuideModel No.Running HeadCPU Host Software Upgrade Procedure CPU Card5.6 CPU Host Software Upgrade ProcedureThis section provides proc

Strany 196

Reference Guide5-43CPU Card CPU Host Software Upgrade Procedure9. In COM 1 window, set BITs per second to “9600” (leave other settings as is) click OK

Strany 197 - Tx ABCD BITS

5-44 Reference GuideModel No.Running HeadSoftware Download Procedures CPU Card5.6.3.1 Upgrade from 5.0.0 to 5.2.0Follow the steps listed below to perf

Strany 198

Reference Guide5-45CPU Card Software Download Procedures5.7.2 XMODEM Protocol Binary DownloadFollow the steps listed below to perform an XMODEM protoc

Strany 199

5-46 Reference GuideModel No.Running HeadSoftware Download Procedures CPU Card5.7.3 Pre-TFTP Binary Upload/Download PreparationTo perform binary (bin)

Strany 200

Reference Guide5-47CPU Card Software Download Procedures4. The binary buffer area appears, and one of the buffers will display an active state. The ot

Strany 201

viii Reference GuideModel No.Running HeadContents8.3.3 Data Diagnostics...

Strany 202

5-48 Reference GuideModel No.Running HeadCPU Card Error Messages CPU Card5.8 CPU Card Error MessagesRefer to Appendix B in the System Reference Guide

Strany 203

Reference Guide5-49CPU Card CPU Card Specifications5.10 CPU Card SpecificationsCPU Card 8803LED IndicatorsOperation Green for normal operation. Red fo

Strany 204

5-50 Reference GuideModel No.Running HeadCPU Card Specifications CPU Card

Strany 205

Reference Guide6-1Interface Card IntroductionChapter 6Interface Card6.1 IntroductionThis chapter provides specific installation, configuration, and tr

Strany 206

6-2 Reference GuideModel No.Running HeadInterface Card Descriptions Interface CardFigure 6-1. INF-E Interface Card6.2.1.1 Card Jumper/Switch SettingsT

Strany 207 - 4.21.1 WAN Link to WAN Link

Reference Guide6-3Interface Card Interface Card Descriptions6.2.1.3 External Sync PanelWhen installed in a two-sided chassis, the INF-E card may be us

Strany 208

6-4 Reference GuideModel No.Running HeadInterface Card Descriptions Interface CardFigure 6-3. Two-Sided Chassis, Back View with External Sync Panel In

Strany 209 - Figure 4-52. The TADS screen

Reference Guide6-5Interface Card Interface Card DescriptionsThe pins shown in JP1 are used to wrap the wires from an externally provided clocking sour

Strany 210 - 4.21.4 Monitor Circuit

6-6 Reference GuideModel No.Running HeadInterface Card Descriptions Interface Card6.2.2 INF+M Card Description (8923)The INF+M card has an internal mo

Strany 211

Reference Guide6-7Interface Card Interface Card Descriptions6.2.3 INF Card Description (8924)The INF card does not have a modem and does not accept ex

Strany 212

Reference GuideixContentsAppendix B Error MessagesB.1 Introduction ...

Strany 213 - 4.21.5 Split Circuit

6-8 Reference GuideModel No.Running HeadInterface Card User Screens and Settings Interface Card6.3 Interface Card User Screens and Settings6.3.1 Inter

Strany 214

Reference Guide6-9Interface Card Interface Card User Screens and SettingsTable 6-2. Interface Card Main Screen Actions6.3.1.1 Setting the System Date

Strany 215 - 4.21.6 Release

6-10 Reference GuideModel No.Running HeadInterface Card User Screens and Settings Interface CardTable 6-3. Interface Card Option Settings and Defaults

Strany 216

Reference Guide6-11Interface Card Interface Card User Screens and Settingsconnection panel (see Figure 6-4). This panel allows for up to two external

Strany 217 - Action Function

6-12 Reference GuideModel No.Running HeadInterface Card User Screens and Settings Interface CardEXT FRAMEIf EXT RATE is e1, set this option to crc or

Strany 218

Reference Guide6-13Interface Card Interface Card User Screens and Settings6.3.2 Call Profile ScreenTo enter a new call profile, first press “f” in the

Strany 219

6-14 Reference GuideModel No.Running HeadInterface Card User Screens and Settings Interface CardTable 6-4. Call Profile Screen ActionsTable 6-5. Call

Strany 220

Reference Guide6-15Interface Card Interface Card User Screens and SettingsCALLED #The Called Number is the full telephone number of the device you are

Strany 221

6-16 Reference GuideModel No.Running HeadInterface Card User Screens and Settings Interface CardIMUX CALLThe IMUX Call field has no application on thi

Strany 222 - 4.25 Power Supply Redundancy

Reference Guide6-17Interface Card Interface Card User Screens and SettingsPRESENT. INDCTRThe Present Indicator field determines whether or not the cal

Strany 223 - 4.26 CPU Card Redundancy

Product DescriptionRelease 5.2 is a major host release for the 5.x platform. This release includes all the feature/functionality of the host 5.x relea

Strany 224

x Reference GuideModel No.Running HeadContentsC.6.3.1 OCU-DP 10 Card External Connectors and Pinouts...C-50C.7 FRAD Cards ...

Strany 225 - 4.27 WAN Card Redundancy

6-18 Reference GuideModel No.Running HeadInterface Card User Screens and Settings Interface Card6.3.3 Signaling Conversion Table ScreenSignaling conve

Strany 226

Reference Guide6-19Interface Card Interface Card User Screens and SettingsThe E&M portion of the Signaling Conversion Table Screen is also used fo

Strany 227

6-20 Reference GuideModel No.Running HeadInterface Card User Screens and Settings Interface CardThe identification numbers for the integrated access c

Strany 228

Reference Guide6-21Interface Card Interface Card User Screens and SettingsTable 6-7 list the “AT” commands and the associated function. All “AT” comma

Strany 229 - 4.28 ADPCM Card Redundancy

6-22 Reference GuideModel No.Running HeadInterface Card User Screens and Settings Interface Card6.3.5 Ports ScreenYou also must configure each of the

Strany 230

Reference Guide6-23Interface Card Interface Card User Screens and SettingsPROTOCOLFor the VT-100 terminal port, the Protocol setting is always ui (use

Strany 231

6-24 Reference GuideModel No.Running HeadInterface Card User Screens and Settings Interface Card6.3.6 Interface Card Ports and FunctionalityThe Interf

Strany 232

Reference Guide6-25Interface Card Interface Card User Screens and Settings6.3.7 Using the Node PortThe Node Port allows the system to report ACO (Alar

Strany 233 - CPU Card

6-26 Reference GuideModel No.Running HeadInterface Card Error Messages Interface Card6.4 Interface Card Error MessagesRefer to Appendix B in the Syste

Strany 234

Reference Guide6-27Interface Card Interface Card Troubleshooting6.5.2 Alarm Reporting ProblemsThe Interface card also provides a relay contact closure

Strany 235 - 5.3.1 CPU Card Main Screen

Reference GuidexiContentsC.14.1.1 FXO 2W*8-6 Card External Connector and Pinouts... C-80C.14.2 FXS Coin Card (8149)...

Strany 236

6-28 Reference GuideModel No.Running HeadInterface Card Specifications Interface Card6.6 Interface Card SpecificationsInterface Cards (Models 8922, 89

Strany 237

Reference Guide6-29Interface Card Interface Card SpecificationsModem Port (Model 8923260 and 892260 only)Connector Female 6-pin RJ-11C socketElectrica

Strany 238

6-30 Reference GuideModel No.Running HeadInterface Card Specifications Interface Card

Strany 239

Reference Guide7-1WAN Card IntroductionChapter 7WAN Card7.1 IntroductionThis chapter provides installation, configuration, and troubleshooting informa

Strany 240

7-2 Reference GuideModel No.Running HeadWAN Card Descriptions WAN Card7.2.2 WAN DUAL Card Description (8010)The WAN DUAL card connects to two T1 or E1

Strany 241 - PRT MIN&INFO

Reference Guide7-3WAN Card WAN Card Descriptions7.2.3 WAN-U Card Description (8011)The WAN-U card is a dual-port card that provides HDSL 2.048 Mbps (E

Strany 242 - 5.4 TCP/IP Network Management

7-4 Reference GuideModel No.Running HeadWAN Card Descriptions WAN Card7.2.4 WAN-R Card Description (8014)The WAN-R card is a dual-T1/E1 card with rela

Strany 243

Reference Guide7-5WAN Card WAN Module DescriptionsNote:The WAN HDSL card doesn’t support line powering, WAN HDSL card redundancy or TR08.Note:This T1/

Strany 244

7-6 Reference GuideModel No.Running HeadWAN Module Descriptions WAN CardFigure 7-3. Installing DSX/CEPT ModulesJP14 JP15JP13JP6JP10JP9

Strany 245 - HOST IP ADDR

Reference Guide7-7WAN Card WAN Module Descriptions7.3.1.3 DSX/CEPT Revision F ModuleThe DSX/CEPT Revision F module is shown in Figure 7-4 through Figu

Strany 246

xii Reference GuideModel No.Running HeadContents

Strany 247 - DEFAULT IP SLOT

7-8 Reference GuideModel No.Running HeadWAN Module Descriptions WAN CardFigure 7-6. DSX/CEPT Module Jumpers (T1)Figure 7-7. DSX/CEPT Module Jumpers (T

Strany 248

Reference Guide7-9WAN Card WAN Module DescriptionsFigure 7-8. DSX/CEPT Module Jumpers (E1 75 Ohm)Figure 7-9. DSX/CEPT Module Jumpers (E1 120 Ohms)Jump

Strany 249 - RPT3 COMMUN STR

7-10 Reference GuideModel No.Running HeadWAN Module Descriptions WAN Card7.3.1.4 DSX/CEPT Revision E1+ ModuleThe DSX/CEPT Revision E1+ module (Figure

Strany 250

Reference Guide7-11WAN Card WAN Module DescriptionsFigure 7-14. 120-Ohm E1 Jumper Settings7.3.1.5 DSX/CEPT Revision A1 Through D1 ModulesThe DSX/CEPT

Strany 251

7-12 Reference GuideModel No.Running HeadWAN Module Descriptions WAN CardFigure 7-18. 75-Ohm E1 Jumper SettingsFigure 7-19. 120-Ohm E1 Jumper Settings

Strany 252

Reference Guide7-13WAN Card WAN Module DescriptionsFigure 7-20. Removal of Plastic Standoffs - 811 WAN ModuleWhen assembling and installing the module

Strany 253 - Default TTL

7-14 Reference GuideModel No.Running HeadWAN Module Descriptions WAN CardFigure 7-21. E1 Interface Adapter PanelFor 120-ohm balanced E1 operation, set

Strany 254

Reference Guide7-15WAN Card WAN Module Descriptions7.3.2 CSU Module Description (812)The CSU module is required for Channel Service Unit (CSU) operati

Strany 255

7-16 Reference GuideModel No.Running HeadWAN Module Descriptions WAN Card7.3.4 PairGain T1/HDSL Module Description (821)You must install two PairGain

Strany 256

Reference Guide7-17WAN Card WAN Module Descriptions7.3.4.2 PairGain T1/HDSL Module Jumper/Switch SettingsThe HDSL PairGain module doesn’t have any jum

Strany 257

Reference GuidexiFigures1-1 Front-Loading Chassis with Power Supplies on the Side (891630)...1-21-2 Two-Sided Chass

Strany 258

7-18 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN Card7.4 WAN Card User Screens and Settings7.4.1 T1 CSU and DSX Setting

Strany 259 - Packets Sent

Reference Guide7-19WAN Card WAN Card User Screens and SettingsTable 7-3. T1 CSU and DSX Main Screen ActionsTable 7-4 lists the CSU/DSX settings on the

Strany 260

7-20 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardTable 7-4. T1 CSU and DSX Option Settings and DefaultsNotes:1. The

Strany 261 - TX Wait for Buffer

Reference Guide7-21WAN Card WAN Card User Screens and SettingsSTATEIn the standby state, the WAN port is electrically disconnected from the network. S

Strany 262 - 5.5 IP Packet Routing

7-22 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardSLIP LIMThe Slip Limit defines how many bits of wander the WAN por

Strany 263 - CPU Card IP Packet Routing

Reference Guide7-23WAN Card WAN Card User Screens and SettingsTable 7-6. AIS/ALM SettingsIn a cross-connect system, the options available for D4 or E

Strany 264 - IP Packet Routing CPU Card

7-24 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardLOCAL LBThe Local Loopback setting allows you to loop the full T1/

Strany 265

Reference Guide7-25WAN Card WAN Card User Screens and SettingsLB ADDRThe Loopback Address setting, when used in conjunction with the Channel Loopback

Strany 266

7-26 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardANSI T1.403 specification be used. Performance statistics are also

Strany 267

Reference Guide7-27WAN Card WAN Card User Screens and SettingsThe WAN links between the Device and the System Unit (A, B, A1, and B1) are called tribu

Strany 268

xii Reference GuideModel No.Running Head3-4 Two-Sided Chassis Mounting Holes...

Strany 269

7-28 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN Card7.4.2 E1 CEPT/HDSL SettingsFigure 7-27 shows the WAN Card Main Scr

Strany 270 - 5.5.1 nX64 Screen

Reference Guide7-29WAN Card WAN Card User Screens and SettingsTable 7-7. E1 HDSL Screen ActionsTable 7-8. E1 HDSL Screen Option Settings and Default

Strany 271

7-30 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN Card4. If there is no redundant WAN card in the appropriate slot, the

Strany 272

Reference Guide7-31WAN Card WAN Card User Screens and SettingsLINE LBThe Line Loopback setting controls looping of the full E1 line back to the networ

Strany 273

7-32 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardCOM/NMS RPThe Communications/Network Management System Report sett

Strany 274 - 5.6.2 Laptop Setup

Reference Guide7-33WAN Card WAN Card User Screens and Settings7.4.3 WAN HDSL Card Main ScreenFigure 7-28 shows the WAN HDSL Card Main Screen for PairG

Strany 275 - 5.6.3 Upgrade Preparation

7-34 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardTable 7-9. WAN HDSL Card Main Screen ActionsTable 7-10 lists the

Strany 276 - 5.7.1 CPU Swap

Reference Guide7-35WAN Card WAN Card User Screens and Settings2. The “LINE CODE” field is set to “auto” and is determined by the HDSL module and set a

Strany 277

7-36 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardTable 7-11. DS0-to-SLC-96 Time Slot ConversionAIS/ALMThe AIS/ALM

Strany 278

Reference Guide7-37WAN Card WAN Card User Screens and SettingsLINE LBThe default setting for Line Loopback for the WAN HDSL card is n/a. LOCAL LBThe L

Strany 279

Reference Guidexiii4-31 Cross-Connect Circuit Type Selection ...4-554-32

Strany 280 - 5.9 CPU Card Troubleshooting

7-38 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN Cardcommands, it is recommand that you send an off command before send

Strany 281 - 5.10 CPU Card Specifications

Reference Guide7-39WAN Card WAN Card User Screens and SettingsThe choice of c-fdl disables telco-side capability to access performance-monitoring info

Strany 282

7-40 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardThe following notification procedure is followed:1. A Loss of Sign

Strany 283 - Interface Card

Reference Guide7-41WAN Card WAN Card User Screens and Settings7.4.4 Cross-Connect (XCON)The Cross-Connect (Xcon) command in the Main WAN screen allows

Strany 284

7-42 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardFigure 7-30. T1 WAN Cross-Connect Screen (display only)Node_1

Strany 285 - 6.2.1.3 External Sync Panel

Reference Guide7-43WAN Card WAN Card User Screens and Settings7.4.5 Performance DataAll WAN cards gather performance data. The performance data for a

Strany 286

7-44 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardTable 7-13 lists the actions available from the Performance Data S

Strany 287

Reference Guide7-45WAN Card WAN Card User Screens and SettingsLOFCThe Loss of Frame Count (LOFC) is the number of times a Loss Of Frame (LOF) is decla

Strany 288

7-46 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN Card7.4.6 Far-End Performance DataThe Far-End Performance Data Screen

Strany 289

Reference Guide7-47WAN Card WAN Card User Screens and SettingsPress “y” to clear the statistics, or “n” to leave the screen contents intact. To view t

Strany 290

xiv Reference GuideModel No.Running Head5-9 Typical Network Statistics Screen, Page 1 ...

Strany 291

7-48 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardLOFCThe Loss of Frame Count (LOFC) is the accumulation of the numb

Strany 292

Reference Guide7-49WAN Card WAN Card User Screens and SettingsTable 7-15. Test Screen ActionsTable 7-16. WAN Card Test Screen Option Settings and De

Strany 293

7-50 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardSYNCThe Synchronization (SYNC) field tells you if the integrated B

Strany 294

Reference Guide7-51WAN Card WAN Card User Screens and SettingsELAPThe Elapsed time setting shows the running tally of the total number of seconds duri

Strany 295 - 6.3.2 Call Profile Screen

7-52 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardTable 7-17. Adtran E1/HDSL Screen ActionsTable 7-18. Adtran E1/HD

Strany 296

Reference Guide7-53WAN Card WAN Card User Screens and SettingsQLTY LP1This parameter indicates the measure of signal quality correlated to noise margi

Strany 297 - RATE MULTIPLIER

7-54 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardFigure 7-35 shows the number of Errored Seconds (ES), Severely Err

Strany 298

Reference Guide7-55WAN Card WAN Card User Screens and SettingsIn 15-minute intervals, 12 historical time periods are shown on the left side of the scr

Strany 299 - BCAST. PHONES

7-56 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN Card7.4.10 PairGain T1/HDSL ScreenFigure 7-37 displays the WAN T1/HDSL

Strany 300

Reference Guide7-57WAN Card WAN Card User Screens and SettingsTable 7-20. PairGain T1/HDSL Module Screen Actions Table 7-21. PairGain T1/HDSL Module S

Strany 301 - 6.3.4.1 Identification

Reference Guidexv7-25 DS0 Time Slot Loopback ...7-247-

Strany 302 - 6.3.4.4 Terminal Security

7-58 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardCIRCUIT IDA Circuit ID is defined as a group of one or more DS0 ti

Strany 303 - AT Command Function

Reference Guide7-59WAN Card WAN Card User Screens and SettingsFigure 7-38. System Loopbacks towards Master ModuleFigure 7-39. PairGain T1/HDSL System

Strany 304 - 6.3.5 Ports Screen

7-60 Reference GuideModel No.Running HeadWAN Card User Screens and Settings WAN CardFRAMINGThe Framing parameter selects the framing mode of the T1 fr

Strany 305 - HANDSHAKE

Reference Guide7-61WAN Card WAN Card User Screens and SettingsLB STATEThe Loopback State setting changes when a WAN loopback is both present and opera

Strany 306

7-62 Reference GuideModel No.Running HeadPARS Screen WAN Card7.5 PARS ScreenFigure 7-40 displays the PARS Screen for the WAN card. To go to this scree

Strany 307 - 6.3.7 Using the Node Port

Reference Guide7-63WAN Card PARS ScreenTable 7-24. WAN Card Test Screen Options Settings and DefaultsPARS must be made aware of the time slot(s) used

Strany 308 - 6.5.1 User Interface Problems

7-64 Reference GuideModel No.Running HeadPARS Screen WAN CardFigure 7-42. WAN Cross-Connect ScreenFigure 7-42 shows the WAN Cross-connect screen after

Strany 309

Reference Guide7-65WAN Card PARS ScreenFigure 7-43. System (Main) Cross-Connect Screen in PARS MODEFigure 7-43 shows the System (Main) cross-connect s

Strany 310

7-66 Reference GuideModel No.Running HeadPARS Screen WAN Card7.5.1 Implementation of PARSThere are certain rules and guidelines to follow when PARS is

Strany 311

Reference Guide7-67WAN Card PARS Screen7.5.2 Ring Network Traffic FlowFigure 7-44 below, shows Ring Network Traffic Flow under normal conditions. The

Strany 312

xvi Reference GuideModel No.Running HeadC-19 ALR 28+14 Card Jacks ...

Strany 313 - WAN Card

7-68 Reference GuideModel No.Running HeadPARS Screen WAN Card7.5.3 One Link is LostIf the link from IAD 1 to IAD 2 fails, then the traffic is rerouted

Strany 314

Reference Guide7-69WAN Card PARS Screen7.5.4 Two Links are Lost, One IAD is Isolated from the RingIf the link from IAD 1 to IAD 2, and the link from I

Strany 315 - Figure 7-2. WAN-U DUAL Card

7-70 Reference GuideModel No.Running HeadPARS Screen WAN Card7.5.5 Two Links are Lost, Two IADs are Separated from the RingIf the link from IAD 1 to I

Strany 316

Reference Guide7-71WAN Card PARS Screen7.5.6 Integrated Access Device FunctionalityIn order to offer PARS feature, the integrated access device will p

Strany 317 - 7.3 WAN Module Descriptions

7-72 Reference GuideModel No.Running HeadPARS Screen WAN CardFigure 7-49 shows user card termination in PARS mode. Time slots assigned to the user car

Strany 318

Reference Guide7-73WAN Card PARS ScreenFigure 7-50. PARS Normal Operation Mode using four IAD NodesA four node configuration operating in PARS mode is

Strany 319

7-74 Reference GuideModel No.Running HeadPARS Screen WAN Card7.5.8 Line Protection - Link FailureWhen WAN links fail, the ring will break. The integra

Strany 320

Reference Guide7-75WAN Card PARS ScreenFigure 7-52. PARS Rerouting (two nodes)Figure 7-52 shows detail of PARS mode for two nodes with the link betwee

Strany 321

7-76 Reference GuideModel No.Running HeadWAN Card Error Messages WAN Card7.6 WAN Card Error MessagesRefer to Appendix B in the System Reference Guide

Strany 322

Reference Guide7-77WAN Card WAN Card Specifications7.8 WAN Card SpecificationsWAN Cards (Models 8000, 8010, 8011, 8014 and 8015 T1/E1)PhysicalModel Nu

Strany 323

Reference GuidexviiTables1-1 Card Slots for Front-Loading Chassis with Power Supplies on the Side ...1-31-2 Two-Sided Chassis

Strany 324

7-78 Reference GuideModel No.Running HeadWAN Card Specifications WAN CardCSU InterfaceBit Rate and Tolerance 1.544 Mbps + 32 ppmNo. of T1 WAN Links pe

Strany 325 - Remove all plastic standoffs

Reference Guide7-79WAN Card WAN Card SpecificationsE1 InterfaceBit Rate and Tolerance 2.048 Mbps + 50 ppmNo. of E1 WAN Links per module 1Max. No. per

Strany 326

7-80 Reference GuideModel No.Running HeadWAN Card Specifications WAN CardStandards CompatibilityAT&T TR43801 Digital Channel Bank Requirements and

Strany 327

Reference Guide8-1System Testing and Diagnostics IntroductionChapter 8System Testing and Diagnostics8.1 IntroductionThis chapter describes the integra

Strany 328

8-2 Reference GuideModel No.Running HeadUser Card Diagnostics System Testing and DiagnosticsNote:*Applicable only for the E1-HDSL plug-in module. Also

Strany 329

Reference Guide8-3System Testing and Diagnostics User Card Diagnostics8.3.2 Voice DiagnosticsThe software-initiated diagnostics supported are voice ca

Strany 330 - 7.4.1 T1 CSU and DSX Settings

8-4 Reference GuideModel No.Running HeadUser Card Diagnostics System Testing and Diagnostics8.3.3 Data DiagnosticsData diagnostics support varies amon

Strany 331

Reference Guide8-5System Testing and Diagnostics User Card DiagnosticsEIA530 HSU 2-portV.35 HSU 2-portEIA530/V.35 HSU 4-portSRUOCU-DP 2/5/10-portDS0-D

Strany 332

8-6 Reference GuideModel No.Running HeadSystem with Cross-Connect Option System Testing and Diagnostics8.4 System with Cross-Connect Option8.4.1 Circu

Strany 333

Reference Guide8-7System Testing and Diagnostics System with Cross-Connect OptionVoice without SignalingVoice with SignalingSingle Data DS0(64 Kbps)Su

Strany 334

Model No.Running HeadSystem CardsCPU XCON (8803)The 8803 CPU XCON supports complex applications requiring more than two WAN ports and the ability to c

Strany 335 - Table 7-6. AIS/ALM Settings

xviii Reference GuideModel No.Running Head7-9 WAN HDSL Card Main Screen Actions...

Strany 336 - LOCAL LB

8-8 Reference GuideModel No.Running HeadBenefits of Built-In Diagnostics System Testing and Diagnostics8.5 Benefits of Built-In DiagnosticsThe real po

Strany 337 - ESF/NMS RP

Reference Guide8-9System Testing and Diagnostics Benefits of Built-In DiagnosticsFigure 8-1. Built-In Diagnostics ExampleL o c a l D T E V . 3 5 H S U

Strany 338

8-10 Reference GuideModel No.Running HeadBenefits of Built-In Diagnostics System Testing and DiagnosticsFigure 8-2. Built-In Diagnostics Example (cont

Strany 339

Reference Guide8-11System Testing and Diagnostics Performance Monitoring8.6 Performance MonitoringThe integrated access system provides non-intrusive

Strany 340 - 7.4.2 E1 CEPT/HDSL Settings

8-12 Reference GuideModel No.Running HeadPerformance Monitoring System Testing and Diagnostics8.6.3 Frame Relay Performance MonitoringThe Frame Relay

Strany 341

Reference GuideA-1Appendix ASystem Standards and SpecificationsA.1 IntroductionThis appendix lists the integrated access system standards, specificati

Strany 342

A-2 Reference GuideModel No.Running HeadA.2 Standards CompatibilityThe following is a comprehensive list of standards that the System Chassis, Common

Strany 343

Reference GuideA-3Interface CardsITU-T V.28 Electrical characteristics for unbalanced double-current interchange circuitsG.703 Physical/Electrical Cha

Strany 344

A-4 Reference GuideModel No.Running HeadSafety and EMC of WAN CardsBellcore GR-63-CORE Issue 1 Network Equipment-Building System (NEBS) Requirements:

Strany 345

Reference GuideA-5E&M CardsBell System TR433801 Digital Channel Bank Requirements and Objectives - November 1982TR-NWT-000057 Functional Criteria

Strany 346

Reference GuidexixC-33 OCU-DP 5 Jack Signals Pinouts ... C-49C-34 O

Strany 347

A-6 Reference GuideModel No.Running HeadBRI Cards (Models 8260 and 8261)ANSI T1.601 ISDN Basic Access Interface for Use on Metallic Loops for Applicat

Strany 348

Reference GuideA-7HSU CardsBellCore GR-63-CORE Issue 1 Network Equipment-Building System (NEBS) Requirements: Physical ProtectionITU-T V.35 Data Trans

Strany 349

A-8 Reference GuideModel No.Running HeadA.3 Chassis StandardsA.3.1 DimensionsNote:Weight is weight of empty chassis with backplanes and power distribu

Strany 350

Reference GuideA-9A.3.2 Chassis PowerA.3.3 EnvironmentA.3.3.1 Ambient Temperature and HumidityAmbient temperature and humidity as per GR-63-CORE R4-6

Strany 351 - RDNT RULES

A-10 Reference GuideModel No.Running HeadA.3.3.3 AirflowConvection cooled (no fans required). Except for Model 891930 Power Enhanced Chassis.A.3.3.4 F

Strany 352

Reference GuideA-11A.3.6 Cable/Power Connections•Chassis Model 891630 - front panel•Chassis Model 891830 - rear panel•Chassis Model 891930 - front pan

Strany 353 - 7.4.4 Cross-Connect (XCON)

A-12 Reference GuideModel No.Running HeadA.3.8 Number of SlotsNote:Note 1 - 8 slots on the 8916 are multi-purpose. Four (4) will accept either Server

Strany 354

Reference GuideA-13A.4 System Power Supplies and ConvertersThe following is a list of standards for the integrated access system power supplies, conve

Strany 355 - 7.4.5 Performance Data

A-14 Reference GuideModel No.Running HeadModel 8905 Power Converter 120/240 VAC to -48 VDC, 100 W, CE MarkedInput Voltage 90 Vrms to 260 VrmsInput Fre

Strany 356

Reference GuideA-15A.4.1 Power Supply CompatibilityA.4.2 External Talk Battery FusesPower SourcesAC Power Supply -48V Power Supply-48V Converter

Strany 357

xx Reference GuideModel No.Running Head

Strany 358

A-16 Reference GuideModel No.Running HeadA.5 Card SpecificationsA.5.1 Dimensions and Power ConsumptionItem Height Width Depth Weight PowerCommon Equip

Strany 359

Reference GuideA-17Note:*These products have been Manufacturing Discontinued (MD), but are supported under this product host code for backward compati

Strany 360 - 7.4.7 Test Screen

A-18 Reference GuideModel No.Running HeadA.5.2 Card Current MeasurementsCard Name and Description+5VDCStndby Active-5VDCStndby Active+12VDCStndby Acti

Strany 361

Reference GuideA-19A.5.3 Pre-Installation Card SetupThe table shown below lists all system user cards that require pre-installation setup. Refer to th

Strany 362

A-20 Reference GuideModel No.Running HeadA.6 Part Number / Acronym TableThe following table details the part number of each card or peripheral listed

Strany 363 - 7.4.8 Adtran E1/HDSL Screen

Reference GuideA-21A.7 FCC RequirementsThe three tables below outline the FCC Registration Information for Part 1, Part 2 and Part 3 for these system

Strany 364

A-22 Reference GuideModel No.Running HeadA.8 UK Requirements Clearance (mm) Creepage (mm)Voltage Used or Generated By Host or Other Cards2.0 2.4 (3.8)

Strany 365 - (local 15-minute interval)

Reference GuideA-23A.9 Year 2000 ComplianceAll products are compliant with Bellcore Requirements GR-2945, Year 2000 Generic Requirements: Systems and

Strany 366

A-24 Reference GuideModel No.Running Head

Strany 367

Reference GuideB-1Appendix BError MessagesB.1 IntroductionThis appendix lists the integrated access system error messages. One of these messages may a

Strany 368

Reference Guide1-1System Overview IntroductionChapter 1System Overview1.1 IntroductionThis chapter describes the various chassis models used by the in

Strany 369

B-2 Reference GuideModel No.Running HeadAll available PVCs are already taken.The number of PVCs available on the FRAD Card Main Screen has been exceed

Strany 370

Reference GuideB-3Both WAN’s cannot be in test mode.You cannot use the test option on both sides of a cross-connect simultaneously.Broadcast cannot be

Strany 371 - Module (or HiGain HRU)

B-4 Reference GuideModel No.Running HeadCannot do it in Viewer mode.You are logged in under the Viewer password, but that level of access does not all

Strany 372

Reference GuideB-5Can’t initialize modem.The Interface card modem was not initialized.Card already installed.You cannot use the Configuration option o

Strany 373 - *REMOTE*

B-6 Reference GuideModel No.Running HeadCommand rejected. Switch in progress.The command was not executed because a redundancy switch is in progress.C

Strany 374 - 7.5 PARS Screen

Reference GuideB-7Each WAN can have only one d-chan.You cannot assign two D-channels to the same WAN port.Empty field is not allowed.You cannot assign

Strany 375 - WAN Card PARS Screen

B-8 Reference GuideModel No.Running HeadFR circuit is not defined.You cannot assign a user circuit for an undefined Frame Relay PVC.FR port and DLCI m

Strany 376 - PARS Screen WAN Card

Reference GuideB-9Invalid date/time format.You have entered an invalid date or time.Invalid Dlci value.The DLCI number you chose is invalid.Invalid en

Strany 377

B-10 Reference GuideModel No.Running HeadInvalid sub address.You cannot assign the same subaddress number to two different user ports on the FRAD Card

Strany 378 - 7.5.1 Implementation of PARS

Reference GuideB-11Modification can’t be saved while test is active.You cannot make changes in this screen while a test is in progress.Module is not i

Strany 379

1-2 Reference GuideModel No.Running HeadChassis Types System Overview1.2 Chassis Types1.2.1 Front-Loading Chassis with Power Supplies on the Side (891

Strany 380 - 7.5.3 One Link is Lost

B-12 Reference GuideModel No.Running HeadNo d-i mode for this slot.In a redundant cross-connect system, you cannot assign the drop-and-insert (d-i) mo

Strany 381

Reference GuideB-13No Voice Compress. WAN card using ALL resources.No ADPCM card is currently available for voice compression.Not applicable for S/T c

Strany 382

B-14 Reference GuideModel No.Running HeadOnly one ADPCM redundant in the system.You cannot make more than one ADPCM a redundant card in the system.Onl

Strany 383

Reference GuideB-15Port already configured for Remote Terminal.This port is already configured for use with a remote terminal.Port has PVC(s) allocate

Strany 384

B-16 Reference GuideModel No.Running HeadPVC has user circuits active. No changes allowed.You cannot deactivate a Frame Relay PVC with active user cir

Strany 385

Reference GuideB-17Restricted field.You cannot access the Superuser password field on the CPU Card Main Screen. This password is factory-assigned.Sele

Strany 386

B-18 Reference GuideModel No.Running HeadSR TS overlapping.The subrate circuit assigned does not allow enough space for a previously assigned circuit

Strany 387

Reference GuideB-19TS 16 cannot be used with v&s.You cannot assign a voice circuit with signaling to time slot 16 of an E1 WAN port.TS 16 is alrea

Strany 388 - 7.7 WAN Card Troubleshooting

B-20 Reference GuideModel No.Running Head

Strany 389 - 7.8 WAN Card Specifications

Reference GuideC-1Appendix CPinoutsC.1 IntroductionThis appendix describes the pinouts of the card connectors used to attached circuits and devices to

Strany 390

Reference Guide1-3System Overview Chassis TypesTable 1-1. Card Slots for Front-Loading Chassis with Power Supplies on the SideType of Card# of CardsSl

Strany 391 - E1 HDSL Interface

C-2 Reference GuideModel No.Running HeadC.2 Interface CardsC.2.1 INF-E Card (8922)C.2.1.1 INF-E Card External Connector and PinoutsFigure C-1 shows th

Strany 392

Reference GuideC-3Using the COM2 PortThe COM2 jack provides an RJ48 DTE connection to an external DTE device. Figure C-2 shows the COM2 jack pin locat

Strany 393 - Chapter 8

C-4 Reference GuideModel No.Running HeadUsing the RS-485 Node PortThe RS-485 Node port allows you to activate external alarms that alert on-site perso

Strany 394

Reference GuideC-5Using the Control Terminal PortThe RS-232 Control Terminal Port allows you to connect the integrated access system to a local VT100-

Strany 395 - 8.3.2 Voice Diagnostics

C-6 Reference GuideModel No.Running HeadUsing the External Sync PortThe External Sync Port allows you to connect up to two external clocking sources f

Strany 396 - 8.3.3 Data Diagnostics

Reference GuideC-7Using the Management PortConnect an external computer or other device to the jack for alarm reporting locally. This is a DB-9 male c

Strany 397

C-8 Reference GuideModel No.Running HeadWAN Port ConnectionsThe NET jack allows you to connect the system’s WAN card ports to incoming and outgoing T1

Strany 398 - 8.4.1 Circuit Diagnostics

Reference GuideC-9Table C-6. NET Jack Signal PinoutsWAN Link Designation Pin FunctionWAN 1-1 T1 47 Rx from NetworkWAN 1-1 RI 22 Rx from NetworkWAN 1-1

Strany 399

C-10 Reference GuideModel No.Running HeadC.2.2 INF+M Card (8923)C.2.2.1 INF+M Card External Connector and PinoutsFigure C-8 shows the INF+M card front

Strany 400

Reference GuideC-11Using the Modem PortThe internal modem of the INF+M card is an asynchronous, ITU-T V.22bis modem. It allows remote access to the te

Strany 401 - Figure 3

1-4 Reference GuideModel No.Running HeadChassis Types System Overview1.2.2 Two-Sided Chassis (891830)Figure 1-2 shows the front of a two-sided chassis

Strany 402

C-12 Reference GuideModel No.Running HeadUsing the RS-485 Node PortThe RS-485 Node port allows you to activate external alarms that alert on-site pers

Strany 403 - 8.6 Performance Monitoring

Reference GuideC-13Using the Control Terminal PortThe RS-232 Control Terminal Port allows you to connect the integrated access system to a local VT100

Strany 404

C-14 Reference GuideModel No.Running HeadUsing the Management PortConnect an external computer or other device to the jack for alarm reporting locally

Strany 405 - Appendix A

Reference GuideC-15WAN Port ConnectionsThe NET jack allows you to connect the system’s WAN card ports to incoming and outgoing T1/E1 lines. This jack

Strany 406 - A.2 Standards Compatibility

C-16 Reference GuideModel No.Running HeadTable C-11. NET Jack Signal PinoutsWAN Link Designation Pin FunctionWAN 1-1 T1 47 Rx from NetworkWAN 1-1 RI 2

Strany 407 - WAN Cards

Reference GuideC-17C.2.3 INF Card (8924)The INF card does not have a modem and does not accept external synchronization clocks. In all other respects,

Strany 408

C-18 Reference GuideModel No.Running HeadThe INF card uses faceplate connectors that are electrically similar to those of the INF-E and INF+M cards pr

Strany 409 - OCU-DP Card

Reference GuideC-19Connect pins 4 and 5 to provide an open relay contact to the external device upon occurrence of an alarm. Or, connect pins 3 and 5

Strany 410

C-20 Reference GuideModel No.Running HeadC.3 Alarm CardsC.3.1 ALR 4+4 Card (8401)C.3.1.1 ALR 4+4 Card External Connectors and PinoutsThe ALR 4+4 Card

Strany 411 - SRU Card

Reference GuideC-21C.3.2 ALR 4+3PF Card (8402)C.3.2.1 ALR 4+3PF Card External Connectors and PinoutsThe ALR 4+3PF Card has a 50-pin Amphenol female co

Strany 412 - A.3 Chassis Standards

Reference Guide1-5System Overview Chassis TypesFigure 1-3. Two-Sided Chassis Rear View (891830)IF U1 U2 U3 U4 U5 U6 U7 U8R1 R5R4R3R2IF U1 U2 U3 U4 U5

Strany 413 - A.3.3 Environment

C-22 Reference GuideModel No.Running HeadC.3.3 ALR 28+14 Card (8403)C.3.3.1 ALR 28+14 Card External Connectors and PinoutsExternal Alarm Equipment Con

Strany 414 - A.3.4 Equipment Handling

Reference GuideC-23Table C-16. ALR 28+14 Card Alarm Sensor PinoutsSensor Desig.J3ConnectorPin Sensor Desig.J4ConnectorPin1 sense - 12 15 sense - 12sen

Strany 415 - A.3.7 Mounting

C-24 Reference GuideModel No.Running HeadTable C-17. ALR 28+14 Card Alarm Switch PinoutsSwitch #Contact TypeForm Desig.J3ConnectorPin # Switch #Cont

Strany 416 - A.3.8 Number of Slots

Reference GuideC-25Voice Circuit ConnectionBetween the Amphenol connectors is a standard RJ-11 connector for interfacing with a 2-wire, 600-ohm voice

Strany 417

C-26 Reference GuideModel No.Running HeadC.4 HSU CardsC.4.1 Two-Port HSU530/35 Card (8202)C.4.1.1 Two-Port HSU Card External Connectors and PinoutsThe

Strany 418

Reference GuideC-27Figure C-22. Two-Port HSU 530/35 Jack Pin OrientationTable C-19. Two-Port HSU 530/35 Jack PinoutsPin Function Direction1 Cable Shi

Strany 419 - Manufacturer Part Number

C-28 Reference GuideModel No.Running HeadC.4.2 HSU-T V11 Card (8203)C.4.2.1 HSU-T V11 Card External Connectors and PinoutsThe HSU-T V11 Card has two D

Strany 420 - A.5 Card Specifications

Reference GuideC-29Table C-20. HSU-T V11 Jack PinoutsPin Function DCE Mode DTE Mode1 Cable Shield -- --2 Send Data A Input Input3 Receive Data A Outpu

Strany 421

C-30 Reference GuideModel No.Running HeadC.4.3 HSU 35 Card (8212)C.4.3.1 HSU 35 Card External Connectors and PinoutsThe HSU 35 Card has two DB-25 jack

Strany 422

Reference GuideC-31C.4.4 HSU-AD 530/35 Card (8213)C.4.4.1 HSU-AD 530/35 Card External Connectors and PinoutsThe HSU-AD 530/35 Card has two DB-26 jacks

Strany 423

1-6 Reference GuideModel No.Running HeadChassis Types System OverviewTable 1-2. Two-Sided Chassis Card SlotsType of Card# of CardsSlots Used NotesCPU

Strany 424

C-32 Reference GuideModel No.Running HeadRS530/V.35 JacksThe RS-530/V.35 jacks allow you to connect the card to two external CPE devices. The electric

Strany 425 - A.7 FCC Requirements

Reference GuideC-33RS-366 JacksThe HSU-AD 530/35 Card RS-366 jacks allow you to connect the system to external CPE devices for RS-366 dialing. These a

Strany 426 - A.8 UK Requirements

C-34 Reference GuideModel No.Running HeadC.4.5 HSU-T V35 Card (8214)C.4.5.1 HSU-T V35 Card External Connectors and PinoutsThe HSU-T V35 Card has two D

Strany 427 - A.9 Year 2000 Compliance

Reference GuideC-35Figure C-29. HSU-T V35 Card Jack Pin OrientationTable C-24. HSU-T V35 Card Jack Pinouts1. Use cable P/N 000-01260F if HSU-T V35 car

Strany 428

C-36 Reference GuideModel No.Running HeadC.4.6 Four-Port HSU 530/35 Card (8215)C.4.6.1 Four-Port HSU 530/35 Card External Connectors and PinoutsThe fo

Strany 429 - Error Messages

Reference GuideC-37Table C-25. Four-Port HSU 530/35 Jack PinoutsPin Function Direction1 Cable Shield --2 Send Data A Input3 Receive Data A Output4 RT

Strany 430

C-38 Reference GuideModel No.Running HeadC.4.7 Four-Port HSU*4E 530/35 Card (8216)C.4.7.1 Four-Port HSU*4E 530/35 Card External Connectors and Pinouts

Strany 431

Reference GuideC-39Table C-26. Four-Port HSU*4E 530/35 Jack PinoutsPin Function Direction1 Cable Shield --2 Send Data A Input3 Receive Data A Output4

Strany 432

C-40 Reference GuideModel No.Running HeadC.4.8 HSU Card CablesTable C-27, Table C-28, and Table C-29 represent a matrix used for connecting cables to

Strany 433

Reference GuideC-41Table C-29. HSU to Cable Matrix (DCE Provides Clock)HSU CARD DCE PROVIDES CLOCKRS530 V.35 RS4498202 NO SWITCHES8202 WITH SWITCHES82

Strany 434

Reference Guide1-7System Overview Chassis Types1.2.3 Front-Loading Chassis with Enhanced Power Supply (891930)Figure 1-4 shows the front-loading chass

Strany 435

C-42 Reference GuideModel No.Running HeadC.5 SRU CardsC.5.1 SRU 232*10 Card (8220)C.5.1.1 SRU 232*10 Card External Connector and PinoutsThe SRU 232*10

Strany 436

Reference GuideC-43Table C-30. SRU 232*10 Card Jack PinoutsConnector Pin Signal Name Direction1RCLKTo DTE2RLSDTo DTE3TCLKTo DTE4 GND N/A5RDTo DTE6TDF

Strany 437

C-44 Reference GuideModel No.Running HeadC.5.2 SRU 232*10 C&D Bus Card (8221)C.5.2.1 SRU 232*10 C&D Bus Card External Connector and PinoutsThe

Strany 438

Reference GuideC-45Table C-31. SRU 232*10 C&D Bus Card Jack PinoutsConnector Pin Signal Name Direction1RCLKTo DTE2RLSDTo DTE3TCLKTo DTE4 GND N/A5

Strany 439

C-46 Reference GuideModel No.Running HeadC.6 OCU-DP CardsC.6.1 OCU-DP 2 Card (8249)C.6.1.1 OCU-DP 2 Card External Connectors and PinoutsInstall the OC

Strany 440

Reference GuideC-47Table C-32. OCU-DP 2 Jack Signals PinoutsRJ-48 Pin Signal Name Direction1 R1 input2 T1 input3-- --4-- --5-- --6-- --7 T output8 R

Strany 441

C-48 Reference GuideModel No.Running HeadC.6.2 OCU-DP 5 Card (8241)C.6.2.1 OCU-DP 5 Card External Connectors and PinoutsThe OCU-DP 5 Card has five sta

Strany 442

Reference GuideC-49Table C-33. OCU-DP 5 Jack Signals PinoutsRJ-48 Pin Signal Name Direction1 R1 input2 T1 input3-- --4-- --5-- --6-- --7 T output8 R

Strany 443

C-50 Reference GuideModel No.Running HeadC.6.3 OCU-DP 10 Card (8246)C.6.3.1 OCU-DP 10 Card External Connectors and PinoutsFigure C-36 shows the 10 RJ-

Strany 444

Reference GuideC-51Table C-34. OCU-DP 10 Jack Signals PinoutsRJ-48 Pin Signal Name Direction1 R1 input2 T1 input3-- --4-- --5-- --6-- --7 T output8

Strany 445

Voice CardsThis host code release supports the following voice cards:•E&M E&M 2W*8 (8108), E&M 2713Hz (8117), E&M 4W*8ER (8119)E&

Strany 446

1-8 Reference GuideModel No.Running HeadChassis Types System OverviewThe power enhanced chassis works in a specific environment relating to applicatio

Strany 447

C-52 Reference GuideModel No.Running HeadC.7 FRAD CardsC.7.1 FRAD 232*10 Card (8231)C.7.1.1 FRAD 232*10 Card External Connectors and PinoutsThe FRAD 2

Strany 448

Reference GuideC-53Table C-35. FRAD 232*10 Card Jack Signal PinoutsMale RJ-48 Pin Signal Name Direction1 RCLK output2 RLSD output3 TCLK output4 GND -

Strany 449 - Appendix C

C-54 Reference GuideModel No.Running HeadC.8 DS0-DP CardsC.8.1 DS0-DP 4 Card (8254)C.8.1.1 DS0-DP 4 Card External Connector and PinoutsThe DS0-DP 4 Ca

Strany 450 - C.2 Interface Cards

Reference GuideC-55Table C-36. DS0-DP 4 Card Jack PinoutsPin Description CLK Direction Mode1 GND --- ---2 N/C --- ---3 XMT CLK A int To DTE G.703 Cont

Strany 451 - Figure C-2. RJ48 (COM2) Jack

C-56 Reference GuideModel No.Running HeadC.9 B7R CardsC.9.1 B7R Card (8228)C.9.1.1 B7R Card External Connector and PinoutsThe B7R card has ten modular

Strany 452

Reference GuideC-57Table C-37. B7R Card Jack Signal PinoutsMale RJ-48 Pin # Signal Name Direction1 * RCLK output2 RLSD output3 * TCLK output4 GND -5

Strany 453

C-58 Reference GuideModel No.Running HeadC.10 BRI CardsC.10.1 BRI U*8 Card (8260)C.10.1.1 BRI U*8 Card External Connectors and PinoutsThe BRI U*8 Card

Strany 454

Reference GuideC-59C.10.2 BRI-SC U*8 Card (8261)C.10.2.1 BRI-SC U*8 Card External Connectors and PinoutsThe BRI-SC U*8 Card has a 50-pin, Amphenol-typ

Strany 455 - Using the Management Port

C-60 Reference GuideModel No.Running HeadC.10.3 BRI-ST*8 Card (8262)C.10.3.1 BRI-ST*8 Card External Connectors and PinoutsThe BRI-ST*8 Card has a 50-p

Strany 456

Reference GuideC-61Table C-40. BRI-ST*8 Card Jack Signal PinoutsPort Designation Pin #1Xmt–T0261Xmt–R011Rcv–T0271Rcv–R022Xmt–T1292Xmt–R142Rcv–T1302Rcv

Strany 457

Reference Guide1-9System Overview Chassis TypesFigure 1-6. Power Supply and Ringer Supports for Power Enhanced Chassis (891930)Power Supply andRinger

Strany 458 - C.2.2 INF+M Card (8923)

C-62 Reference GuideModel No.Running HeadC.10.4 BRI-2 U*8-SC Card (8263)C.10.4.1 BRI-2 U*8-SC Card External Connectors and PinoutsThe BRI-2 U*8-SC Car

Strany 459 - Figure C-9. MODEM Jack

Reference GuideC-63C.10.5 BRI-2 U*8 Card (8264)C.10.5.1 BRI-2 U*8 Card External Connectors and PinoutsThe BRI-2 U*8 Card has a 50-pin, Amphenol-type j

Strany 460

C-64 Reference GuideModel No.Running HeadC.10.6 PM-IOR Card (8280)C.10.6.1 PM-IOR Card External Connectors and PinoutsThe PM-IOR Card has two RJ-48 fo

Strany 461

Reference GuideC-65Table C-43. PM-IOR Card Console Port “CO” Jack Pinouts1. Pins 8 and 6 in the DB-25 connectors are connected internally.2. Not conne

Strany 462

C-66 Reference GuideModel No.Running HeadC.11 Server CardsC.11.1 ACS-MCC Server Card (8813)C.11.1.1 ACS-MCC External Connectors and PinoutsThe ACS-MCC

Strany 463 - Figure C-13. NET Jack

Reference GuideC-67C.11.2 ACS-ATM Card (8820)C.11.2.1 ACS-ATM Card External Connectors and Signal PinoutsThe ATM Card connects to the LAN via a single

Strany 464

C-68 Reference GuideModel No.Running HeadC.11.3 ACS-PRI/BRI Card (8811)C.11.3.1 ACS-PRI/BRI Card External Connectors and PinoutsThe ACS-PRI/BRI card h

Strany 465 - C.2.3 INF Card (8924)

Reference GuideC-69C.11.4 IPR 10BT Card (8831)C.11.4.1 IPR 10BT Card External Connectors and PinoutsThe IPR 10BT card has an Ethernet interface port a

Strany 466

C-70 Reference GuideModel No.Running HeadC.12 E&M CardsC.12.1 E&M 2W*8 Card (8108)C.12.1.1 E&M 2W*8 Card External Connectors and PinoutsTh

Strany 467

Reference GuideC-71Table C-49. E&M 2W*8 Card Jack PinoutsPort Designation Pin Port Designation Pin1T 265R 131R 15T1 391T1 275R1 141R1 25E 401E 285

Strany 468 - C.3 Alarm Cards

1-10 Reference GuideModel No.Running HeadChassis Types System OverviewTable 1-3. Card Slots for Front-Loading Chassis with Enhanced Power Supplies on

Strany 469 - C.3.2 ALR 4+3PF Card (8402)

C-72 Reference GuideModel No.Running HeadC.12.2 E&M 4W*8ER Card (8119)C.12.2.1 E&M 4W*8ER Card External Connectors and PinoutsThe card has a 5

Strany 470 - C.3.3 ALR 28+14 Card (8403)

Reference GuideC-73Table C-50. E&M 4W*8ER Card Jack PinoutsPort Designation Pin Port Designation Pin1T 265R 131R 15T1 391T1 275R1 141R1 25E 401E 2

Strany 471

C-74 Reference GuideModel No.Running HeadC.12.3 E&M 4W*8ER Card (8118)C.12.3.1 E&M 4W*ER Card External Connectors and PinoutsThe card has a 50

Strany 472

Reference GuideC-75Table C-51. E&M 4W*8ER Card Jack PinoutsPort Designation Pin Port Designation Pin1T 265R 131R 15T1 391T1 275R1 141R1 25E 401E 2

Strany 473 - Figure C-20. RJ-11 Jack

C-76 Reference GuideModel No.Running HeadC.12.4 E&M 4W*8-2713Hz Card (8117)C.12.4.1 E&M 4W*8-2713Hz Card External Connectors and PinoutsThe ca

Strany 474 - C.4 HSU Cards

Reference GuideC-77Table C-52. E&M 4W*8-2713Hz Card Jack PinoutsPort Designation Pin Port Designation Pin1T 265R 131R 15T1 391T1 275R1 141R1 25E 4

Strany 475 - Pin Function Direction

C-78 Reference GuideModel No.Running HeadC.13 FXS CardsC.13.1 FXS 2W*4-6 Card (8125)C.13.1.1 FXS 2W*4-6 Card External Connectors and PinoutsThe FXS 2W

Strany 476 - C.4.2 HSU-T V11 Card (8203)

Reference GuideC-79C.13.2 FXS 2W*8-6 Card (8219)C.13.2.1 FXS 2W*8-6 Card External Connectors and PinoutsThe FXS 2W*8-6 Card has a 50-pin Amphenol jack

Strany 477

C-80 Reference GuideModel No.Running HeadC.14 FXO CardsC.14.1 FXO 2W*8-6 Card (8139)C.14.1.1 FXO 2W*8-6 Card External Connector and PinoutsThe FXO 2W*

Strany 478 - C.4.3 HSU 35 Card (8212)

Reference GuideC-81C.14.2 FXS Coin Card (8149) C.14.2.1 Card External Connectors and PinoutsThe FXS Coin Card has a 50-pin Amphenol jack located on it

Strany 479 - C-25 shows these jacks

Reference Guide1-11System Overview U.S. and European Chassis Configuration1.3 U.S. and European Chassis ConfigurationThe chassis can be configured to

Strany 480

C-82 Reference GuideModel No.Running HeadC.14.3 FXO Coin Card (8159)C.14.3.1 Card External Connector and PinoutsThe FXO Coin Card has a 50-pin Ampheno

Strany 481 - RS-366 Jacks

Reference GuideC-83C.15 P-Phone CardsC.15.1 P-Phone Cards PPO (8131) PPS (8121)C.15.1.1 P-Phone External Card Connectors and PinoutsThe P-Phone PPO an

Strany 482 - C.4.5 HSU-T V35 Card (8214)

C-84 Reference GuideModel No.Running HeadTable C-58. P-Phone PPO and PPS Card Tip/Ring Connector PinoutsPin No. Signal Pin No. Signal1R126 T12nc 27 n

Strany 483

GlossaryIntroductionThis Appendix lists the glossary of terms used in the telecommunications industry today.AALATM Adaption LayerABCD bitsThe bits tha

Strany 484

Model No.Running HeadAISAlarm Indication SignalAIMATM Inverse Multiplexera-lawE1 companding standard used in the conversion between analog and digita

Strany 485

B-channelIn ISDN, a full-duplex, 64 kbps (“bearer”) channel that carries user data.BECNBackward Explicit Congestion NotificationBERBit Error Rate, the

Strany 486

Model No.Running HeadCCITTConsultative Committee for International Telegraph and Telephone, now known as the ITU (International Telecommunications Un

Strany 487

CLConnectionless ServiceCPECustomer Premises EquipmentCODECCOder/DECoder (a device that encodes and decodes signals)compandingNon-linear reduction of

Strany 488 - C.4.8 HSU Card Cables

Model No.Running HeadD4A common T1 framing format, consisting of 12 frames. Also known as SF framing.DACSDigital Access and Cross-connect System (an

Strany 489 - RS530 V.35 RS449

DMADirect Memory AccessDPODial-Pulse OriginatingDPTDial-Pulse TerminatingDRAMDynamic Random Access MemoryDS0Digital Signal - Zero, the standard bandwi

Strany 490 - C.5 SRU Cards

1-12 Reference GuideModel No.Running HeadU.S. and European Chassis Configuration System Overview

Strany 491

Model No.Running HeadDTEData Terminal EquipmentDTRData Terminal ReadyDXDuplex SignalingE1Digital 2.048 Mbps line rate, widely used in countries outsi

Strany 492

E&M CardAn E&M voice card for this system.ETS1European Telecommunications Standards InstituteF4Four-frame multiframe structure used in T1 sign

Strany 493

Model No.Running HeadFRSFrame Relay Server, a card used in this system.FSFrame Signaling bits (T1 line).FTFrame Terminal bits (T1 line)FT1Fractional

Strany 494 - C.6 OCU-DP Cards

HDB3High-Density Bipolar Order of 3, three-zero maximum coding for E1 lines. Provides a fourth zero violation for data bytes.HDLCHigh-Level Data Link

Strany 495

Model No.Running HeadIPInternet ProtocolIPRInternet Protocol RouterISPInternet Service ProviderITUInternational Telecommunications Union (previously

Strany 496 - C.6.2 OCU-DP 5 Card (8241)

LTLine TerminationLULTLT Like UnitLUNTNT Like UnitMACMedia Access ControlMBSNortel’s Meridian Bussiness Set. An electronic telephone set capable of ha

Strany 497

Model No.Running Headmu-lawT1 companding standard used in the conversion between analog and digital signals in PCM systems.NEBENear End Block Error.

Strany 498 - C.6.3 OCU-DP 10 Card (8246)

OOSOut of Service, an indication that a system element has failed.OSIOpen Systems InterconnectionPAMPulse Amplitude ModulationPBXPrivate Branch Exchan

Strany 499

Model No.Running HeadPPPPoint-to-Point ProtocolPPSPPhone Foreign Exchange Station Card. An interface at the end of the FX line connected to MBS.proto

Strany 500 - C.7 FRAD Cards

SESSeverly Errored SecondsSFSuperframe, a T1 framing format consisting of 12 frames. Also known as D4 framing.SLCSubscriber Loop Carrier (made by

Strany 501

Reference Guide2-1Applications IntroductionChapter 2Applications2.1 IntroductionBy virtue of its open design, this system is capable of serving many d

Strany 502 - C.8 DS0-DP Cards

Model No.Running HeadTADTest Access DigroupTCP/IPTransmission Control Protocol/Internet ProtocolTDMTime-Division MultiplexingTELNETAn application pro

Strany 503

UNIUser Network InterfaceUser cardA Voice card, Data card, or Alarm card.VBRVariable Bit RateVCVirtual ChannelVCLVirtual Channel LinkVPVirtual PathVPC

Strany 504 - C.9 B7R Cards

Model No.Running HeadZCSZero Code Suppression

Strany 505

2-2 Reference GuideModel No.Running HeadSample Applications Applications2.2 Sample Applications2.3 Voice Modules and Applications2.3.1 Foreign Exchang

Strany 506 - C.10 BRI Cards

Reference Guide2-3Applications Voice Modules and ApplicationsTest functionality also includes the ability to generate test tones (300Hz, 1 kHz, 3 kHz

Strany 507 - C.10.2 BRI-SC U*8 Card (8261)

2-4 Reference GuideModel No.Running HeadVoice Modules and Applications Applications2.3.3 E&M CardThis integrated access system supports two varian

Strany 508 - C.10.3 BRI-ST*8 Card (8262)

Reference Guide2-5Applications Voice Modules and Applications2.3.4 Voice Channel Bank ApplicationThis is the simplest application which can be used by

Strany 509 - Port Designation Pin #

Model No.Running HeadData CardsThis host code release supports the following data cards:•HSU Two-Port HSU 530/35 (8202), HSU-T V11 (8203), HSU 35 (821

Strany 510

2-6 Reference GuideModel No.Running HeadVoice Modules and Applications Applications2.3.5 TR008 ApplicationBellCore’s TR008 standard describes the requ

Strany 511 - C.10.5 BRI-2 U*8 Card (8264)

Reference Guide2-7Applications Voice Modules and Applications2.3.6 T1-E1 Conversion ApplicationThe Digital Access and Cross-connect System (DACS) capa

Strany 512 - C.10.6 PM-IOR Card (8280)

2-8 Reference GuideModel No.Running HeadData Modules and Applications Applications2.4 Data Modules and ApplicationsThis integrated access system suppo

Strany 513 - 2. Not connected

Reference Guide2-9Applications Data Modules and Applicationsshould occur when the HSU port and the attached device are connected over a long cable. Th

Strany 514 - C.11 Server Cards

2-10 Reference GuideModel No.Running HeadData Modules and Applications Applications2.4.2 HSU Application ExampleA major Health Maintenance Organizatio

Strany 515 - C.11.2 ACS-ATM Card (8820)

Reference Guide2-11Applications Data Modules and Applicationsincorporates a built-in V.14 Async-to-sync converter to avoid over-sampling and consequen

Strany 516

2-12 Reference GuideModel No.Running HeadData Modules and Applications Applications2.4.4 FRAD CardThe 8231 Frame Relay Assembler/Disassembler (FRAD) u

Strany 517 - C.11.4 IPR 10BT Card (8831)

Reference Guide2-13Applications Data Modules and ApplicationsFigure 2-6. IAD FRAD Card Application2.4.5 OCU-DP CardThe OCU-DP (Office Channel Unit - D

Strany 518 - C.12 E&M Cards

2-14 Reference GuideModel No.Running HeadData Modules and Applications ApplicationsEach OCU-DP port can be independently programmed to operate at 2.4,

Strany 519

Reference Guide2-15Applications Data Modules and ApplicationsAll three remote loop backs are latching loop backs. These latching loop backs are:•loop

Strany 520

Server CardsThis host code release supports the following server cards:•ADPCM ADPCM 64 (8871)•FRS FRS (881160), FRS International (881163)•MCC MCC (88

Strany 521

2-16 Reference GuideModel No.Running HeadData Modules and Applications ApplicationsFigure 2-7. BRI Terminal Extension ApplicationThe BRITE mode suppor

Strany 522

Reference Guide2-17Applications Data Modules and ApplicationsThe 8261 BRI “U” Card has all of the functionality of the 8260, however, switching betwee

Strany 523

2-18 Reference GuideModel No.Running HeadData Modules and Applications ApplicationsSoftware-initiated diagnostics supported on the DS0-DP/G.703 card i

Strany 524

Reference Guide2-19Applications ADPCM Voice Compression ServerThe remote systems must be configured with the TCP/IP CPU software option. Remote units

Strany 525

2-20 Reference GuideModel No.Running HeadADPCM Voice Compression Server Applications2.5.1 PBX to PBX Trunk ApplicationFigure 2-10 shows the IAD with a

Strany 526 - C.13 FXS Cards

Reference Guide2-21Applications ADPCM Voice Compression ServerFigure 2-11. IAD in an ISDN-based ACD System2.5.3 Wireless Base Station ApplicationIn th

Strany 527 - C.13.2 FXS 2W*8-6 Card (8219)

2-22 Reference GuideModel No.Running HeadISDN Primary Rate Interface (PRI) Server ApplicationsFigure 2-12. IAD in a Wireless Base Station ApplicationB

Strany 528 - C.14 FXO Cards

Reference Guide2-23Applications ISDN Primary Rate Interface (PRI) Server•Optional ISDN ‘U’ InterfacesThree ISDN PRI Server Cards are supported:•8840A

Strany 529 - C.14.2 FXS Coin Card (8149)

2-24 Reference GuideModel No.Running HeadISDN Primary Rate Interface (PRI) Server Applications(NFAS). The system is limited to 8 WAN links. Thus the s

Strany 530 - C.14.3 FXO Coin Card (8159)

Reference Guide2-25Applications ISDN Primary Rate Interface (PRI) ServerFigure 2-13 shows that three customers are subscribing to ISDN services. Each

Strany 531 - C.15 P-Phone Cards

Model No.Running HeadUsing this Reference DocumentationReference documents for this product consists of several individual reference guides, each cove

Strany 532

2-26 Reference GuideModel No.Running HeadISDN Primary Rate Interface (PRI) Server ApplicationsBy grooming the PBX and CODEC PRI circuits onto a single

Strany 533 - Glossary

Reference Guide2-27Applications ISDN Primary Rate Interface (PRI) Server2.6.4 Integrated ISDN Access with SINAThis integrated access system is used to

Strany 534

2-28 Reference GuideModel No.Running HeadISDN Primary Rate Interface (PRI) Server Applications2.6.5 Data Backup and Bandwidth on DemandThis integrated

Strany 535

Reference Guide2-29Applications ISDN Primary Rate Interface (PRI) Server2.6.6 PRI to FXS terminationThis integrated access system is used to connect c

Strany 536

2-30 Reference GuideModel No.Running HeadISDN Primary Rate Interface (PRI) Server ApplicationsWhen an incoming call is received by the system, it firs

Strany 537

Reference Guide2-31Applications ISDN Primary Rate Interface (PRI) ServerFigure 2-19. Bi-Directional Default Routing2.6.7.4 Alternate routingAlternate

Strany 538

2-32 Reference GuideModel No.Running HeadManagement Channel Concentrator (MCC) Server Applications2.6.7.5 DPNSS Trunk RoutingDigital Private Network S

Strany 539

Reference Guide2-33Applications Management Channel Concentrator (MCC) Serverinterfaces are used, each interface has a local IP address. Unnumbered int

Strany 540

2-34 Reference GuideModel No.Running HeadManagement Channel Concentrator (MCC) Server ApplicationsFigure 2-21. MCC Card in a Multilevel Concentration

Strany 541

Reference Guide2-35Applications Frame Relay Access and Concentration Server2.8 Frame Relay Access and Concentration ServerThis section highlights the

Strany 542

User Card Reference GuidesThere are four individual Reference Guides that cover the User Cards for this product. They are: The Voice Card Reference Gu

Strany 543

2-36 Reference GuideModel No.Running HeadFrame Relay Access and Concentration Server Applications2.8.1 Frame Relay Switch Port SavingsFigure 2-22 show

Strany 544

Reference Guide2-37Applications Frame Relay Access and Concentration Server2.8.2 Frame Relay and Internet Service ProvisioningThe inherent flexibility

Strany 545

2-38 Reference GuideModel No.Running HeadFrame Relay Access and Concentration Server Applications2.8.3 IDSL Service ProvisioningThis integrated access

Strany 546

Reference Guide2-39Applications Frame Relay Access and Concentration Server2.8.4 Grooming and Concentration in Cellular NetworksFigure 2-25 shows how

Strany 547

2-40 Reference GuideModel No.Running HeadFrame Relay Access and Concentration Server Applications2.8.5 Frame Relay Concentration at Hub SitesIn the ap

Strany 548

Reference Guide2-41Applications ATM Server Card2.8.6 Frame Relay Server SpecificationsThere can be up to three Frame Relay server cards in an integrat

Strany 549

2-42 Reference GuideModel No.Running HeadATM Server Card ApplicationsStandards-based ATM adaptation for voice, video, and data This feature enables th

Strany 550

Reference Guide2-43Applications ATM Server Card•Analog PBXs/Key Systems•Digital PBXs•Nx56K/64K Data terminal equipment•Video Codecs•Transparent LAN Ex

Strany 551

2-44 Reference GuideModel No.Running HeadATM Server Card Applications2.9.2 Interactive Distance Learning/Tele-MedicineThe integrated access systems’ i

Strany 552

Reference Guide2-45Applications Routing Server2.9.3 ATM Server SpecificationsUp to three ATM server cards can be functional in an integrated access sy

Komentáře k této Příručce

Žádné komentáře